background image

21

Vermont Castings Majestic Products NV360/580 Series

20003565

NV360/580

 

(continued)

Ref.

Description

NV360

NV580

6.

Ceramic tile (single)

57803

57803

7.

Manifold Assembly

10000765

10000765

8a.

Ceramic Hearth Panel (Left)

20002274

20002322

8b.

Ceramic Hearth Panel (Right)

20002275

20002323

9.

Ceramic Panel (Rear)

20002273

20002319

10a.

Ceramic Panel (Left Side)

20002271

20002321

10b.

Ceramic Panel (Right Side)

20002272

20002320

11.

Glass with Gasket

20002205

20002369

12.

Gasket Glass

10000992

10000992

13.

Door Frame Assy

20003710

20003711

14.

Clamp Frame Window

54174

54174

15.

Trim Frame Window (Pb) (w/two magnets)

57483

20002072

16.

Louvre Assembly Top

10000039

20002380

17.

Bottom Louvre Assy.

10000040

20002381

18.

Bottom Louvre Hinge

52356

52356

19.

Deflector Top

54364

20002286

20.

Grate Assembly

20002196

20002442

21a.

Orifice - Front Burner - LP

20003872

20002540

21b.

Orifice - Front Burner - Nat.

53349

20002150

21c.

Orifice - Rear Burner - LP

20002385

10000616

21d.

Orifice - Rear Burner - Nat.

20002498

20003611

22.

Switch On/Off

51842

51842

23a.

Valve - Honeywell VS8421 (Nat.)

10001782

10001782

23b.

Valve - Honeywell VS8421 (LP)

10001759

10001759

24a.

Valve - SIT 820 (Nat.)

52677

52677

24b.

Valve - SIT 820 (LP)

52678

52678

25a.

Pilot Assembly (Nat.)

10002264

10002264

25b.

Pilot Assembly (LP)

10002265

10002265

26.

Electrode Ignitor w/cable SIT24

10001297

10001297

27.

Sensing Electrode w/cable

57885

57885

28.

Pilot Tube 1/8" x 24" long w/fittings

10001296

10001296

29.

Thermocouple 24”

53373

53373

31.

Thermopile 18” RS

51827

51827

32.

Pilot Top Convertible

10002266

10002266

33.

Hood Pilot 3 way

10002385

10002385

34a.

Pilot Orifice #65 - Nat.

10002268

10002268

34b.

Pilot Orifice #35 - LP

10002269

10002269

35.

Ignitor Piezo (SIT Valve)

52464

52464

36a.

Air Shutter - Front - LP

20000680

20000680

36b.

Air Shutter - Rear - LP

20000184

20000680

37.

Air Shutter - Nat.

20000129

20000129

38.

Fan w/ Bracket

54103

54103

39.

Electrical Cord (6ft.)

51865

51865

40.

Fan Temp. Sensor

51704

51704

41.

Speed Control

51738

51738

42.

Speed Control Knob

51882

51882

43.

Remote Switch Kit  (not shown)

53875

53875

44.

Piezo Ignitor Replacement Kit - Honeywell Valve (not  shown)

20000062

20000062

45.

Conversion Kit (Nat. to LP) (not shown)

20003896

20003898

46.

Conversion Kit (LP to Nat.) (not shown)

20003895

20003897

47.

Vent Safety Switch

10002013

10002013–

Содержание NV360

Страница 1: ...e gas suppliers instructions If you cannot reach your gas supplier call the fire department WARNING IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY A FIRE OR EXPLOSION MAY RESULT CAUSING PRO...

Страница 2: ...5 Hearth 5 Framing Finishing 6 Final Finishing 6 Gas Specifications 6 Gas Inlet Manifold Pressures 6 High Elevations 6 Gas Line Installation 6 Remote Switch Installation 7 Alternate Switch Location 7...

Страница 3: ...flammable vapor and liquids This fireplace should not be used as a drying rack for clothing nor should Christmas stocking or decorations be hung in the area of it 9 Under no circumstances should any s...

Страница 4: ...g dimensions Ref NV360 NV580 A 41 1046mm 47 1194mm B 37 953mm 41 1048mm C 36 914mm 42 1067mm D 24 622mm 28 724mm E 7 179mm 7 179mm F 6 152mm 6 152mm G 1 32mm 1 32mm H 19 489mm 23 591mm I 5 140mm 5 140...

Страница 5: ...applies to the distance between the mantel leg if fitted and the fireplace For the correct mounting height and widths refer to Figures 2a 2b and the Mantel Chart below The distances and reference poi...

Страница 6: ...jurisdiction In Canada please consult provincial and or local authorities having jurisdiction for installations at elevations above 4 500 feet 1 370m NV360 NV580 CERTIFIED TO ANSI Z21 50a 1999 CSA 2...

Страница 7: ...sconnect this or any other gas appliance control from the gas line when pressure testing The gas control is equipped with a captured screw type pressure test point therefore it is not necessary to pro...

Страница 8: ...from the bottom of the fire place Maximum vertical height 40 feet 12m Minimum height with two elbows 18 feet 4 6m Elbow requirements allow a maximum of two 90 elbows or four 45 elbows per installatio...

Страница 9: ...12m in height Up to an 8 ft horizontal vent run can be installed within the vent system using a maximum of two 2 90 degree elbows or four 4 45 degree elbows B Vertical installations up to 40 feet 12m...

Страница 10: ...ed at the bottom edge and swings down Operating Instructions Glass Information Clamps Glass Frame Fireplace Front Glass Panel Glass Panel Pull Clamp Hook G584 501 Push Clamp Handle Fig 10 Glass panel...

Страница 11: ...Log Front Right Log Rear Log Front Left Log Top Right Log Top Left LG119 Ember Material Lava Rock Top logs must be placed properly onto notches 4 Place front left log on top of burner left side Align...

Страница 12: ...n gas valve is off Remove glass frame See Window Frame Assembly Removal Section Using a flashlight check the area above the baffle in the combustion dome Clean if necessary Flame Characteristics It is...

Страница 13: ...instruc tions exactly B BEFORE LIGHTING smell all around the heater area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU...

Страница 14: ...Check the flue and venting components for blockage or restrictions Remove the front louvre assembly Locate the sensor Reset the sensor by pressing the reset pin between the two wire terminals Fig 18...

Страница 15: ...Ignitor Supply Line Hooked Up Shut off Valve Open Pilot Stays Lit For Air In The Lines Thermopile Needs A Min 325mv Adjust Pilot Flame Height All Wiring Connections Replace Thermopile Thermocouple Ne...

Страница 16: ...s Jumper wire accross terminals at wall switch if burner comes on replace defective wall switch If okay jumper wires across wall switch wires at valve if burner comes on wires are faulty or connection...

Страница 17: ...tter retaining screw then air shutter Fig 24 Fuel conversion must be completed by qualified personnel LO HI LO HI Hi Lo Knob Cap Lift Open Remove Center Screw CO100 Fig 21 Removing center screw from H...

Страница 18: ...rn unit OFF NOTE Be sure unit is cool 2 Remove glass 3 Remove logs Remove old hearth panels and discard 4 Remove two 2 screws securing grate to hearth pan Fig 28 5 Set left and right panels on hearth...

Страница 19: ...thermopile millivolt gas valve Most of these components may require only an occa sional checkup and cleaning and some may require adjustment If repair is necessary it should be performed by a qualifi...

Страница 20: ...e right to make changes in design materials specifications prices and discontinue colors and products at any time without notice NV360 580 Ref Description NV360 NV580 1 Log Set 20002397 20002071 1a Lo...

Страница 21: ...ve Honeywell VS8421 Nat 10001782 10001782 23b Valve Honeywell VS8421 LP 10001759 10001759 24a Valve SIT 820 Nat 52677 52677 24b Valve SIT 820 LP 52678 52678 25a Pilot Assembly Nat 10002264 10002264 25...

Страница 22: ...x 5 Be sure fan motor does not touch nearby metal Method A Route the 6 1 8m lead fitted to the unit to a con veniently located wall socket Method B If the EB1 receptacle box Pt ZA1200 was cor rectly c...

Страница 23: ...ig 34 Rear ceramic panel placement Decorative Frame Trims A selection of decorative frame trim kits are available for mounting around the outside of the appliance to enhance its visual effect on the r...

Страница 24: ...hop If upon inspection the damage is found to be the fault of the manufacturer repairs will be authorized at no charge to the customer parts and or labor Any part and or component replaced under the p...

Отзывы: