Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23
60
If installing a television (TV) above the appliance, see
Section 2.B.
C. Installing a Television
Figure 10.4 Minimum Vertical and Maximum Horizontal
Dimensions of Combustibles or Painted Surfaces
5
10
11
12
2-1/2
13
14
15
16
17
18
19
32
TO CEILING
9
10
11
12
8
7
6
5
4
3
25
18
Measurement from fireplace
opening to bottom of appliance:
= 33-1/2 IN. (MER36MN)
= 35-1/2 IN. (MER42MN)
Note:
All measurements
in inches.
Note:
Measurement is taken from top of the opening,
Combustible Mantels
Combustible Mantels - Passive Heat Installed
Figure 10.5 Minimum Vertical and Maximum Horizontal
Dimensions of Combustibles - Passive Heat Kit
Installed
6
12
Measurement from fireplace
opening to bottom of appliance:
= 33-1/2 IN. (MER36MN)
= 35-1/2 IN. (MER42MN)
Note:
All measurements
in inches.
Note:
Measurement is taken from top of the opening,
NOT the top of the fireplace.
5
2-1/2
13
14
15
16
17
18
11
12
50
TO CEILING
7
8
9
10
D. Mantel and Wall Projections
WARNING! Risk of Fire!
Comply with all minimum clear-
ances as specified.
Mantel MUST be fastened to wall
with no gaps.
• Framing closer than the minimums listed must be
constructed entirely of non-combustible materials (i.e.,
steel studs, concrete board, etc.).
• No gaps allowed between the wall and the bottom of the
mantel.
•
Combustible mantel legs and wall projections may be
applied over the non-combustible board supplied with
the appliance. Follow guidelines as shown in the figures
below for mantels, mantel legs and wall projections.
• Measurement is taken from top/side of the opening, NOT
the top/side of the appliance.
Mantel requirements are shown in Figures 10.4-10.9.