Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23
58
10
10
Finishing
HIGH TEMPERATURE (300 ºF/ 149 ºC MIN.)
TOP AND SIDE SEAL JOINT
REMOVABLE SURROUND (SHADED AREA)
MAY BE COVERED WITH COMBUSTIBLE
OR NON-COMBUSTIBLE MATERIAL
FACING MATERIAL UP TO 1/2 IN. THICK
MAY BE COMBUSTIBLE - TOP AND SIDES
0 IN.
0 IN.
1-1/8 IN.
0 IN.
FACTORY-INSTALLED NON-COMBUSTIBLE BOARD
DO NOT REMOVE
B
A
FACTORY-INSTALLED
NON-COMBUSTIBLE BOARD
DRYWALL OR
WALL SHEATHING
MATERIAL
NON-COMBUSTIBLE
FINISHING MATERIAL
NO GAP ALLOWED
A
B
MER36MN
inches
40-7/8
41
millimeters
1038
1041
MER42MN
inches
42-7/8
48
millimeters
1089
1219
A. Facing Material
Figure 10.2 Non-combustible Facing Diagram
NOTICE:
Surface temperatures around the appliance
will become warm while the appliance is in operation.
Ensure finishing materials used for all surfaces (floor, walls,
mantels, etc.) will withstand temperatures up to 190
°
F.
Risk of Fire!
DO NOT
apply combustible materials beyond the min-
imum clearances.
Comply with all minimum clearanc-
es to combustibles as specified in this manual.
Ma
-
terials overlapping into non-combustible zones could
ignite and will interfere with air flow through decorative
barrier fronts.
• Metal front of appliance may be covered with non-
combustible materials only.
• Facing and/or finishing materials must not interfere
with air flow through decorative barrier fronts, removal
of decorative barrier fronts or access for service.
• Facing and/or finishing materials must never
overhang into the glass opening.
• Observe all clearances when applying combustible
materials.
• Seal gaps between the finished wall and appliance
top and sides using a 300 ºF minimum sealant. Refer
to Figure 10.1 and Figure 10.2.
• Finishing materials must be installed with no gaps
in order to prevent the escape of heat between the
finishing material and the wall. See Figure 10.1.
WARNING
WARNING!
Risk of Overheating!
DO NOT
allow gap
between finishing materials and front of appliance.
Figure 10.1 Finishing Material Installed
WARNING!
Risk of Overheating!
DO NOT
install
combustible or non-combustible flooring or hearth
material above top of bottom surround. Gap be-
tween bottom of decorative front and top of bottom
surround must be maintained for proper air flow.
Figure 10.3 Required Air Flow Gap
Flooring & Hearth Material (1-1/8 IN. MAX.)
FLOORING OR HEARTH MATERIAL
NOT ALLOWED
ABOVE TOP OF BOTTOM SURROUND
REQUIRED AIR FLOW GAP
DECORATIVE BARRIER FRONT