33
Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23
Figure 4.12
Two Elbows
INSTALLED
HORIZONTALLY
H
1
H
2
V
1
MER36MN
V
1
Minimum
H
1
+ H
2
Maximum
Elbow only
Not Allowed
6 in.
152 mm
Not Allowed
1 ft.
305 mm
4 ft.
1.2 m
1-1/2 ft.
457 mm
11 ft.
3.4 m
2 ft.
610 mm
17 ft.
5.2 m
2-1/2 ft.
762 mm
20 ft.
6.1 m
V
1
+ H
1
+ H
2
= 40 ft. (12.2 m) Maximum
H
1
+ H
2
= 20 ft. (6.1 m) Maximum
V
1
= 1 ft. (305 mm) Minimum
MER42MN
V
1
Minimum
H
1
+ H
2
Maximum
Elbow only
Not Allowed
6 in.
152 mm
Not Allowed
1 ft.
305 mm
2 ft.
610 mm
2 ft.
610 mm
4 ft.
1.2 m
3 ft.
914 mm
6 ft.
1.8 m
4 ft.
1.2 m
8 ft.
2.4 m
6 ft.
1.8 m
12 ft.
3.6 m
10 ft.
3.0 m
20 ft.
6.1 m
V
1
+ H
1
+ H
2
= 40 ft. (12.2 m) Maximum
H
1
+ H
2
= 20 ft. (6.0 m) Maximum
V
1
= 1 ft. (305 mm) Minimum
Top Vent - Horizontal Termination - (continued)
WARNING! Risk of Fire!
Elbow heat shield required
when V
1
= 2 ft. or less. Clearances to combustibles
must be maintained. See Section 5.A.