Measurement from top edge
of opening to bottom of
appliance = 33-1/2 IN. (851 mm)
ROOM CEILING
1-1/2 IN. (2 X 4 FRAMING)
2 IN. MIN.
TV
4 IN. MIN.
(102 mm)
1/2 IN. X 1/2 IN.
WIRE MESH*
*
Wire mesh required for front discharge or open top discharge passive heat installations with discharge
opening of three inches or greater.
Good Faith Guidelines for TV Installations
Above a Fireplace with Passive Heat Option
83-1/2 IN. (2121 mm) MIN.
(Appliance may be
installed off of floor)
WIRE MESH
*
= PASSIVE HEAT
DISCHARGE OPENING
41 IN. MIN. (1041 mm)
(MINIMUM CLEARANCE TO
DISCHARGE OPENING)
NOTE:
The TV installation requirements are the same regardless of whether the Passive Heat kit is installed with a
top discharge, side discharge or open top discharge.
MER36MN: 76 IN. MIN. (1930 mm)
MER42MN 78 IN. MIN. (1981 mm)
(Appliance may be installed
off of floor)
FIREPLACE
OPENING
2 X 4 FRAMING
2 X 4 OR 2 X 6
FRAMING
CHASE CEILING REQUIRED
WITHIN 3 IN. (76 mm) OF TOP
OF OPENING
12 IN. MIN.
**
(305 mm)
**
For information on mantel requirements, refer to Section 2.B (Good Faith TV Guidelines for TV Installations)
and Section 10.C (Mantel and Wall Projections). If a fan is installed, a mantel is required to maintain the Good Faith
guidelines for TV installation. See Section 2.B and Section 2.C.
WARNING! Risk of Fire!
Wire mesh required on bottom of discharge opening when discharge
opening is greater than 3 inches. Secure wire mesh to top of framing.
Good Faith TV Guidelines
Figure 10.17 Good Faith Guidelines for TV Installations Above a Fireplace with Passive Heat Option