Hearth & Home Technologies • DVLINEAR36 Installation Manual • 2569-980 Rev. E • 11/20
26
Figure 4.13
Two Elbows
Top Vent - Horizontal Termination - (continued)
Note
: Use SLP Series
components only.
INSTALLED
HORIZONTALLY
H
1
H
2
V
1
V Minimum
H
1
+ H
2
Maximum
90° Elbow
Not Allowed
1 ft.
305 mm
1 ft.
305 mm
2 ft.
610 mm
2 ft.
610 mm
3 ft.
914 mm
4 ft.
1.2 m
4 ft.
1.2 m
6 ft.
1.8 m
5 ft.
1.5 m
15 ft.
4.6 m
H
1
+ H
2
MAX. =15 ft. (4.6 m)
V
1
+ H
1
+ H
2
MAX. = 40 ft. (12.2 m)
CAUTION:
The SLP-HRC-SS termination caps are
not approved for use with these models.
May lead to
elevated glass temperature that may cause tempered
glass breakage.
Note
: There MUST be a 25% reduction
in total H when using SLP-FLEX Series
(6-5/8 inch) vent except when using
the simple up and out installation. See
Figure 4.10.