11
Hearth & Home Technologies • DVLINEAR36 Installation Manual • 2569-980 Rev. E • 11/20
B.
Appliance Location and
Clearances to
Combustibles
When selecting a location for the appliance it is important
to consider the required clearances to walls
and allow suf
-
ficient clearance for heat management systems venting.
See Figure 3.3.
WARNING!
Risk of Fire or Burns!
Provide adequate
clearance around air openings and for service access.
Due to high temperatures, the appliance should be lo-
cated out of traffic and away from furniture and draperies.
NOTICE:
Illustrations reflect typical installations and are
FOR DESIGN PURPOSES ONLY. Illustrations/diagrams
are not drawn to scale. Actual installation may vary due to
individual design preference.
Figure 3.3 Appliance Locations
A
B
C
D
E
F
DVLINEAR36
Inches
47-1/2
42
66
See Section 10
Mantel and Wall Projections.
15-3/4
17-1/4
Millimeters
1207
1067
1676
400
438
A
E
A
C
TOP VENT
ONE 90
0
ELBOW
ALCOVE
INSTALLATION
D*
TOP VENT
ONE 90° ELBOW
B
F
Refer to Section 10 for mantel and wall
projection information.
Consider the mantel or cabinet system to be
installed and comply with the necessary
requirements for elevated hearth. Refer to
instructions included with cabinet system.
18 in. (457 mm) required
when Passive Heat Side
Discharge Kit is installed.
1/2 IN.