72
Majestic • DBDV36PLATIN, DBDV36PLATIL, DBDV42PLATIN, DBDV42PLATIL Installation Manual • 2454-980 Rev. F • 5/17
A. Vent Components Diagrams
(continued)
Figure 12.10 SLP Series Vent Components
Fire Risk.
• When using SLP-HRC-SS termination cap
on top vented fireplaces, a one foot minimum
vertical vent section is required before installing
first elbow.
13 in.
(330 mm)
15 in.
(381 mm)
8-1/8 in.
(206 mm)
10-7/8 in.
276 mm
10-1/2 in.
267 mm
3°
87°
Effective Length
5-3/4 to 8-3/8 in.
146 to 213 mm
5-1/2 in.
140 mm
8-3/8 in.
213 mm
SLP-HRC-SS
HORIZONTAL TERMINATION CAP
• When using DVP-TB1 termination cap on top vented
fireplaces, a three foot minimum vertical vent section is
required before installing first elbow.
1 in.
(25 mm)
14 in.
(356 mm)
3/8 in. (10 mm)
1 in. (25 mm)
7-1/4 in.
(184 mm)
7-3/4 to 10-3/8 in.
(197 to 264 mm)
DVP-FBHT
FireBrickTermination Cap
WARNING
Extended Heat Shield
12-5/8 IN.
(321 mm)
12-5/8 IN.
(321 mm)
20 IN.
(508 mm)
10-5/8 IN.
(270 mm)
SLP-RDS
ROOF DECK INSULATION SHIELD