Wall Switch Installation for Fan (Optional)

If the box is being wired to a wall mounted switch for use 

with a fan (See Figure 8.3):

•  The power supply for the appliance must be brought into 

a switch box.

•  The power can then be supplied from the switch box to 

the appliance using a minimum of 14-3 with ground wire.

•  At the switch box connect the black (hot) wire and red 

(switch leg) wire to the wall switch as shown.

•  At the appliance connect the black (hot), white (neutral) 

and green (ground) wires to the junction box as shown.

•  Add a 1/4 in. insulated female connector to the red (switch 

leg) wire, route it through the knockout in the face of the 

junction box, and connect to the top fan switch connector 

(1/4 in. male) as shown.

Red

Switch

Switch Box

Red

Black

Black

Green

Green

White

Power

Supply

Wires

White

R

ed

B

la

ck

G

re

en

W

hi

te

Minimum 14-3 AWG
with Ground

Junction Box

Knockout

Figure 8.3.  Junction Box Wired to Wall Switch

Содержание DBDV36PLATIN

Страница 1: ...ified installer service agency or the gas supplier WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury death or property damage Models This applia...

Страница 2: ...hase 12 4 Termination Location and Vent Information A Vent Termination Minimum Clearances 13 B Chimney Diagram 14 C Approved Pipe 15 D Use of Elbows 16 E Measuring Standards 17 F Vent Diagrams 17 5 Ve...

Страница 3: ...power 110 120 VAC provided to the appliance ___________________________ Switch wires properly installed ___________________________ Gas Section 9 Pg 47 48 Proper appliance for fuel type ______________...

Страница 4: ...sinks NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE This appliance is tested and approved as either supplemen tal room heat or as a decorative appliance It should not be factored as primary heat in re...

Страница 5: ...zontally vented gas fu eled heating appliance or equipment The sign shall read in print size no less than one half 1 2 in in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OB STRUCTIONS Inspection The...

Страница 6: ...rvice agency or your dealer C Tools and Supplies Needed Before beginning the installation be sure that the following tools and building supplies are available Tape measure Framing material Pliers Non...

Страница 7: ...parts could impair safe operation DO NOT install damaged in complete or substitute components Keep appliance dry Hearth Home Technologies disclaims any responsibility for and the warranty will be voi...

Страница 8: ...ters K 28 1 2 724 35 1 2 902 L 14 1 4 362 17 3 4 451 M 8 1 2 216 8 1 2 216 N 2 7 8 73 2 7 8 73 O 8 1 2 216 8 1 2 216 P 1 25 1 25 Q 40 7 8 1038 42 7 8 1089 R 21 9 16 548 23 5 8 600 S 32 813 39 991 DBDV...

Страница 9: ...22 867 CRD42 DBDV42PLATIN IL in 35 11 16 25 1 8 44 1 16 1 5 8 6 3 8 34 3 8 36 mm 906 638 1119 41 162 873 914 G D E F A B C DBM36BK DBM42BK DECORATIVE FRONTS INSIDE FIT A B C D E F G A B C D E F G DBM3...

Страница 10: ...lation may vary due to individual design preference Figure 3 3 Appliance Locations A B C D E F G H DBDV36PLATIN IL in 51 42 72 56 5 8 See Section 10 B Mantel Projections 22 17 3 4 8 mm 1295 1067 1829...

Страница 11: ...NG DIMENSIONS Models A B C D E F G H I J Rough Opening Width Rough Opening Height Rough Opening Depth Rough Opening Width Clearance to Ceiling Combustible Floor Combustible Flooring Behind Appliance S...

Страница 12: ...Additionally in regions where cold air infiltration may be an issue the inside surfaces may be sheetrocked and taped or an equivalent method may be used to achieve maximum air tightness To further pr...

Страница 13: ...F TO LOWEST DISCHARGE OPENING 4 Termination Location and Vent Information Fire Risk Maintain vent clearance to combustibles as specified DO NOT pack air space with insulation or other materials Failur...

Страница 14: ...V V V V V V M H or i V G X V H A V V H Electrical Service V K V K V L C V N 6 inches non vinyl sidewalls 12 inches vinyl sidewalls O 18 inches non vinyl soffit and overhang 48 inches vinyl soffit and...

Страница 15: ...to Sec tion 12 A for vent component information and dimensions DO NOT mix pipe fittings or joining methods from differ ent manufacturers The pipe is tested to be run inside an enclosed wall There is...

Страница 16: ...UN RISE E F F E C T I V E L E N G T H Y X X X DVP Pipe Effective Length Rise Run Inches Millimeters Inches Millimeters DVP4 4 102 2 3 4 70 DVP6 6 152 4 1 4 108 DVP12 12 305 8 1 2 216 DVP24 24 610 17 4...

Страница 17: ...Mounting Surface Figure 4 7 Measure to Top of Last Section of Pipe General Rules SUBTRACT 3 ft from the total H measurement for each 90 elbow installed horizontally SUBTRACT 1 1 2 ft from the total H...

Страница 18: ...aps on top vented fireplaces a 6 inch minimum vertical vent section is required before installing first elbow WARNING WARNING Note The DBDV36PLATI DBDV42PLATI series fireplaces can adapt to SLP series...

Страница 19: ...4 6 m 2 1 2 ft 762 mm 20 ft 6 1 m 3 ft 914 mm 25 ft 7 6 m V1 H1 40 ft 12 2 m Maximum H1 25 ft 7 6 m Maximum DBDV42PLATIL LP V1 Minimum H1 Maximum Elbow Only 18 in 457 mm 1 ft 305 mm 3 ft 914 mm 2 ft...

Страница 20: ...2 m 3 ft 914 mm 6 ft 1 8 m 4 ft 1 2 m 8 ft 2 4 m 6 ft 1 8 m 12 ft 3 6 m 10 ft 3 0 20 ft 6 1 m V1 H1 H2 40 ft 12 2 m Maximum H1 H2 20 ft 6 0 m Maximum V1 1 ft 305 mm Minimum INSTALLED HORIZONTALLY H1 H...

Страница 21: ...inued Three Elbows V1 Min H1 Max V2 Min H2 Max Elbow only 2 ft 610 mm 0 in 0 mm 1 ft 305 mm 6 in 152 mm 3 ft 914 mm 6 in 152 mm 2 ft 610 mm 1 ft 305 mm 6 ft 1 8 m 1 ft 305 mm 6 ft 1 8 m 2 ft 610 mm 11...

Страница 22: ...V42PLATIL Installation Manual 2454 980 Rev F 5 17 Top Vent Vertical Termination No Elbow Figure 4 13 Note If installing a vertical vent termination off the top of the ap pliance the flue restrictor sh...

Страница 23: ...lf tapping screws See Figure 4 15 4 Reinstall the exhaust shield Top Vent Vertical Termination continued Note If the DVP 2SL or DVP SLP24 adapter is used with SLP pipe you MUST subtract one number fro...

Страница 24: ...igure 4 16 Top Vent Vertical Termination continued V1 H1 Maximum V2 V1 V2 Min Elbow only 2 ft 610 mm 6 in 152 mm 6 ft 1 8 m 2 ft 610 mm 11 ft 3 4 m 3 ft 914 mm 16 ft 4 9 m 4 ft 1 2 m 20 ft 6 1 m V1 V2...

Страница 25: ...1 V2 V1 H1 H2 V2 V1 V2 Minimum H1 H2 Maximum Elbow only 1 ft 305 mm 1 ft 305 mm 6 in 152 mm 2 ft 610 mm 2 ft 610 mm 1 ft 305 mm 2 ft 610 mm 2 ft 610 mm 2 ft 610 mm 4 ft 1 2 m 4 ft 1 2 m 3 ft 914 mm 9...

Страница 26: ...26 Majestic DBDV36PLATIN DBDV36PLATIL DBDV42PLATIN DBDV42PLATIL Installation Manual 2454 980 Rev F 5 17 Figure 4 18 Rear Vent Horizontal Termination No Elbow H1 16 in 406 mm Maximum H1...

Страница 27: ...t 2 7 m 12 ft 3 7 m 3 ft 914 mm 4 ft 1 2 m 17 ft 5 2 m 20 ft 6 1 m V1 H1 H2 40 ft 12 2 m Maximum H1 3 ft 914 mm Maximum H1 H2 20 ft 6 1 m Maximum H1 H2 V1 INSTALLED HORIZONTALLY H3 H1 H2 V1 H1 Maximum...

Страница 28: ...t 610 mm 1 ft 305 mm 3 ft 914 mm 2 ft 610 mm 5 ft 1 5 m 3 ft 914 mm 7 ft 2 1 m 4 ft 1 2 m 8 ft 2 4 m 5 ft 1 5 m 8 ft 2 4 m V1 H1 40 ft 12 2 m Maximum H1 8 ft 2 4 m Maximum V1 Minimum H1 H2 Maximum Bac...

Страница 29: ...1 m 8 ft 2 4 m 10 ft 3 1 m 8 ft 2 4 m V1 H1 H2 H3 40 ft 12 2 m Maximum No specific restrictions on this value EXCEPT V1 H1 H2 H3 cannot exceed 40 ft 12 2 m Maximum H1 H2 H3 8 ft 2 4 m Maximum H1 Maxim...

Страница 30: ...ination cap WARNING Risk of Fire Coaxial to colinear venting con figuration may only be used in existing non combustible chimney Installation in any other venting application could cause fire Prior to...

Страница 31: ...structions included with DVP 2SL kit Attach the DV 46DVA GCL adapter to the appliance starting collar with 3 1 2 in self tapping screws See Figure 4 27 Rear Vent Remove the rear seal cap and insulatio...

Страница 32: ...M B will be required SLP heat shield designed to be used on a wall 4 3 8 in to 7 5 8 in 111 mm to 194 mm thick If wall thickness is less than 4 3 8 the existing heat shields must be field trimmed If w...

Страница 33: ...on both sides then both wall shield firestops must have a heat shield refer to Section 12 A attached to them See Section 7 F for information for regarding the instal lation of a horizontal termination...

Страница 34: ...ck insu lation around the vent Insulation must be kept back from the pipe to prevent overheating Figure 5 5 Installing Ceiling Firestop Figure 5 6 Installing the Attic Shield INSTALL ATTIC INSULATION...

Страница 35: ...Figure 6 1 Generic Fireplace Shown Cut the seal cap strap across the rectangles next to the disk For rear vent skip this step Figure 6 2 Generic Fireplace Shown Remove the white gasket material coveri...

Страница 36: ...ce Shown To attach the first section of vent pipe make sure to use the fiberglass gasket in the manual bag to seal between the first vent component and the outer fireplace wrap Use 2 self tapping scre...

Страница 37: ...ont to back Shim the appliance as necessary It is acceptable to use wood shims underneath the appliance Secure the appliance to the framing by using nails or screws through the nailing tabs Optional S...

Страница 38: ...minimum continuous exposure rating including the slip section that connects directly to the horizontal ter mination cap Apply a bead of silicone sealant 300 F minimum con tinuous exposure rating insi...

Страница 39: ...bead of silicone sealant 300 F minimum con tinuous exposure rating to the outside of connecting joint after joining sections OR Apply aluminum foil tape 300 F minimum continuous exposure rating to the...

Страница 40: ...Pull carefully to separate the pieces of pipe Figure 7 11 Align and Disassemble Vent Sections Figure 7 10 Rotate Seams for Disassembly C Secure the Vent Sections Vertical runs originating off the top...

Страница 41: ...MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING Figure 7 14 insert Bolt into Brackets NOTICE Failure to properly caulk the roof flashing and pipe seams could permit entry of water Caulk the gap b...

Страница 42: ...t shields must overlap 1 1 2 in 38 mm mini mum There are two sections of the heat shield One section is factory attached to the wall shield firestop The other section is factory attached to the cap Se...

Страница 43: ...of a cap shield to prevent anything or anyone from touching the hot cap NOTICE For certain exposures which require superior resistance to wind driven rain penetration a flashing kit and HRC caps are...

Страница 44: ...reconstruction Follow instructions that come with those accessories Hearth Home Technologies recommends that Intel liFireTM Plus wireless controls be used for their features and functionality with th...

Страница 45: ...g into the appliance junction box to supply power to the unit OR install 4 AA cell batteries not included into the battery pack before use NOTICE Batteries should only be used as a power source in the...

Страница 46: ...d wire At the switch box connect the black hot wire and red switch leg wire to the wall switch as shown At the appliance connect the black hot white neutral and green ground wires to the junction box...

Страница 47: ...have loos ened during shipping and handling WARNING Risk of Fire DO NOT change valve settings This valve has been preset at the factory WARNING Risk of Fire or Explosion High pressure will damage valv...

Страница 48: ...t to close the air shutter Tighten the wing nut NOTICE If sooting occurs provide more air by opening the air shutter MODEL GAS TYPE MIN VENT RUN MAX VENT RUN DBDV36PLATIN NG 1 4 in Full Open DBDV36PLA...

Страница 49: ...efer to Figure 10 1 and Figure 10 2 WARNING Risk of Fire DO NOT apply combustible materials beyond the minimum clearances Comply with all minimum clearances to combustibles as specified in this manual...

Страница 50: ...B maximum is_____ A Inches 2 7 16 3 7 16 4 7 16 5 7 16 6 7 16 7 7 16 Millimeters 62 87 113 138 164 189 B Inches 1 2 3 4 5 Millimeters 25 51 76 102 127 Note Measurement is taken from top of the openin...

Страница 51: ...RIP NOT USED See Figure 10 9 for removal instructions NON COMBUSTIBLE FINISHING MATERIAL 1 IN MAX CRD36 CRD42 Overlap Fit 0 1 Inch Thick Finishing Method Non Combustible Finish Materials Remove Finish...

Страница 52: ...4 Inches Thick FINISHING STRIP NOT USED See Figure 10 9 for removal instructions NON COMBUSTIBLE FINISHING MATERIAL 0 4 IN MAX TOP OF APPLIANCE OPENING Figure 10 7 Inside Fit Decorative Front Finish M...

Страница 53: ...42PLATIL Installation Manual 2454 980 Rev F 5 17 FINISHING STRIPS REMOVED Figure 10 9 Removing Finishing Strips Removal of Finishing Strips NOTICE Remove finishing strips before firing appliance Remov...

Страница 54: ...on the glass frame GLASS ASSEMBLY LATCHES BOTH BOTTOM AND TOP B Remove the Shipping Materials Inspect Grate Remove shipping materials from inside or underneath the firebox The splatter guard is a pie...

Страница 55: ...ration Ember material is shipped with this gas appliance To place the ember material Embers CANNOT be placed directly over ports Care should be taken not to cover the lighting trail of ports from back...

Страница 56: ...05 CAUTION Logs are fragile handle with care Figure 4 LOGSDBDV36PLAT Log Pin Locations Reference Figure 1 and 2 for log identification of logs It is important to lay the logs out in order as shown in...

Страница 57: ...acing the rear of the appliance The bottom end of Log C should rest against the pin and touch the refractory The bark end of Log C should rest in the notch on Log B See Figure 7 Figure 7 Log C Install...

Страница 58: ...otch on the bottom of the log should rest on the horizontal grate tine approximately halfway between the middle and right grate tines The top of Log G rests in the notch of Log A It will be spaced alm...

Страница 59: ...C1 C2 E1 E2 D Figure 3 LOGSDBDVPLAT42 Log Set Assembled Figure 2 LOG E LOG F LOG G LOG H F H G A B C1 F E1 D H G C2 E2 LOG E1 LOG F LOG A LOG B LOG D LOG H LOG C1 PIN 1 PIN 2 NOTICE To simplify the in...

Страница 60: ...C1 C1 NOTCH FOR LOG B 4 LOG D Locate the pin for Log D in Figure 4 Position the log in the appliance as shown in Figure 8 The base of the log wider end will rest against the log pin and will contact t...

Страница 61: ...st on top of Log E1 The log should contact the back refractory 7 LOG G Place Log G into appliance as shown in Figure 11 The narrow end of the log contacts the back refractory and the right side contac...

Страница 62: ...as shown in Figure 14 with the burned out portion toward the center of the appliance The base of the log will be in the right rear corner contacting both the rear and right side refractory The flat bo...

Страница 63: ...187 mm 11 3 8 in 289 mm 1 1 4 in 32 mm 9 1 4 in 235 mm 13 1 4 in 337 mm 1 2 in TYP DVP90ST 90 Elbow 10 in 254 mm 10 in 254 mm 1 in 25 mm DVP FS Ceiling Firestop DVP45 45 Elbow DVP Pipe see chart Effe...

Страница 64: ...minimum of 1 1 2 in 38 mm The heat shield is designed to be used on a wall 4 in to 7 1 4 in 102 mm to 184 mm thick If wall thickness is less than 4 in 102 mm the existing heat shields must be field tr...

Страница 65: ...1 4 in 337 mm RF12 Roof Flashing Cap Shield DRC RADIUS 13 7 8 in 352 mm 9 1 2 in 241 mm 14 in 356 mm COOL ADDM Cap Shield 11 5 8 in 295 mm 5 3 4 in 146 mm 7 1 8 in 181 mm 12 1 8 in 308 mm DVP BEK2 DV...

Страница 66: ...305 mm 12 1 8 in 314 mm 7 1 8 in 181 mm 8 3 4 in 222 mm 1 5 8 in 41 mm 16 7 8 in 429 mm DVP HPC High Performance Cap 1 in 25 mm 14 in 356 mm 3 8 in 10 mm 1 in 25 mm 7 1 4 in 184 mm 7 3 4 to 10 3 8 in...

Страница 67: ...ATION CAP 13 in 330 mm 15 in 381 mm 8 1 8 in 206 mm 10 7 8 in 276 mm 10 1 2 in 267 mm 3 87 Effective Length 5 3 4 to 8 3 8 in 146 to 213 mm 5 1 2 in 140 mm 8 3 8 in 213 mm Figure 12 5 DVP Vent Compone...

Страница 68: ...16 IN 424 mm 13 5 8 IN 346 mm 12 1 2 IN 318 mm 12 1 2 IN 318 mm 20 3 4 IN 527 mm 13 5 8 IN 346 mm EFFECTIVE LENGTH 32 IN 813 mm MIN 35 IN 889 mm MAX A Vent Components Diagrams continued PVI SLP B Pow...

Страница 69: ...5 1 2 IN 394 mm 11 1 2 IN 292 mm 8 IN 203 mm 4 3 8 IN 112 mm 10 IN 254 mm 5 1 4 IN 135 mm 2 1 4 IN 57 mm 9 1 2 IN 241 mm 4 3 4 IN 121 mm 2 1 4 IN 57 mm 1 1 2 IN 38 mm 6 1 4 IN 159 mm Front View Top Vi...

Страница 70: ...ffective Height Length SLP PIPE SLP HVS Horizontal Pipe Support SLP FS Ceiling Firestop SLP WS Wall Shield Firestop DVP SLP24 Adapter 6 1 2 in 165 mm 25 3 16 in 640 mm 8 1 16 in 205 mm 10 7 8 in 276 m...

Страница 71: ...hickness is greater than 7 1 4 in 184 mm a DVP HSM B will be required Heat Shield Term Cap Minimum Effective Length Maximum Effective Length Trap1 3 1 8 in 4 3 4 in 79 mm 121mm Trap2 5 1 4 in 9 1 4 in...

Страница 72: ...206 mm 10 7 8 in 276 mm 10 1 2 in 267 mm 3 87 Effective Length 5 3 4 to 8 3 8 in 146 to 213 mm 5 1 2 in 140 mm 8 3 8 in 213 mm SLP HRC SS HORIZONTAL TERMINATION CAP When using DVP TB1 termination cap...

Страница 73: ...lex Liner Kit DV 46DVA GCL Coaxial Colinear Appliance Connector 768 380A Stainless Steel Flex Pipe DVP 2SL Adapter COAXIAL to COLINEAR VENTING Figure 12 12 Coaxial to Colinear Vent Components SLP HHW2...

Страница 74: ...ach of children See your dealer if you have questions Optional Fan Follow the instructions supplied with the fan kit to operate your fan See your dealer if you have questions Refractory Required Refra...