48
74D0010
CLEANING AND MAINTENANCE
VENT SYSTEM
The fireplace and venting system should be inspected before initial use and at least annually by a quali
-
fied field service person. Inspect the external vent cap on a regular basis to make sure that no debris
is interfering with the airflow. Inspect entire venting system to ensure proper function.
GLASS DOOR
Thoroughly clean the inside of the glass door after using the fireplace for ten hours. Periodically clean
the glass door as necessary.
When cleaning the glass, remember:
•
Do not remove the glass when hot.
Allow glass to cool before removal.
• NEVER use abrasive materials.
• Keep children and pets a safe distance away.
• Never operate the fireplace without the glass door properly secured.
• Never operate the fireplace if the glass is broken.
• Replace any glass that is chipped, cracked, or broken. Replacement glass door assemblies MUST
be supplied by the fireplace manufacturer –
No substitute materials may be used.
•
Handle glass door with care to avoid striking or scratching it on hard objects.
To clean glass door, follow “Glass Removal” procedure outlined in the
Final Installation
section. Film
deposit on the inside of the glass should be cleaned off using a nontoxic, non-corrosive, non-abrasive,
mild-cleaning solution. Simply apply an adequate amount to the glass and wipe off with a damp cloth.
After all maintenance has been completed, re-install glass door.
LOGS
Leave logs installed in the fireplace for cleaning. Vacuum surface of the logs with a brush attachment.
If logs must be removed for cleaning, handle carefully by holding gently at each end. Gloves are
recommended to prevent skin irritation from ceramic fibers. If skin becomes irritated, wash gently
with soap and water. Vacuum surface of logs with brush attachment or brush logs with a soft bristle
brush (i.e. clean, dry paintbrush). To place logs back in the fireplace, see “Log Placement” found in
the
Final Installation
section.
NOTE:
Do not use fluids to clean ceramic fiber logs.
ROCK WOOL
Replace or add rock wool as required following installation instructions in the
Final Installation
section of this manual.
Содержание 400DVBL
Страница 52: ...52 74D0010 2 3 4 5 6 7 illustrated parts lists firebox components ...
Страница 54: ...54 74D0010 illustrated parts lists 1 2 3 4 5 6 7 8 10 11 12 13 14 Standing Pilot Millivolt control 2T 2I 2C 8 ...
Страница 56: ...56 74D0010 illustrated parts lists SIGNATURE COMMAND SYSTEM 0009 SG parts 8 08 1 2 3 4 17 5 6 7 8 9 13 14 15 ...
Страница 64: ...64 74D0010 SEPTEMBER 2008 74D0010 Rev 10 MHSC 149 Cleveland Drive Paris Kentucky 40361 www mhsc com ...