SIGNATURE COMMAND SYSTEM OPERATION INSTRUCTIONS
1. When the master switch is in the ON position (“-”), pressing the ON button and the
OFF button on the Command Center simultaneously will toggle between enabling and
disabling the six-hour shutdown option.
2. After the above operation, one beep (for enabling the six-hour shutdown option) or two
beeps (for disabling the six-hour shutdown option) will be given as confirmation.
Remote Transmitter Learn Function (Default OFF)
1. The RF receiver button located on the control board must be in the on position before the
learn function can begin. Use paper clip to depress button. One beep for RF receiver ON
or two beeps for RF receiver OFF will be given as confirmation.
2. Holding the OFF button on the Command Center while turning on the master switch will
activate the learn function for the transmitter.
3. After the above operation, two beeps will be given and the green LED on the Command
Center will flash for 10 seconds.
4. During the 10 seconds, press the OFF button on a transmitter to learn. Another two beeps
will be given to confirm a successful learning.
Shutting Off the Standing Pilot
To shut off the standing pilot for service or summer shut down, press and hold the ON
button on the Command Center for 3 seconds when the master switch is in the ON position
(“-”) and the main burner is off.
Note
: Pilot will resume the next time system is turned on.
Key Combinations for System Settings
SYSTEM CONFIGURATION/SETUP
(continued)
Function
Operation
Default Setting
Intermittent/Standing
Hold the ON ▲ button while turning on the master switch
Intermittent
Pilot Setup
(Beep once for standing pilot, twice for intermittent pilot)
Pilot
Standing Pilot Temp.
Hold the ON ▲ button 3 seconds (when the master switch
Shutoff
on the main burner is off)
RF Remote Receiver
Push the RF receiver On/Off button on the control board
RF OFF
On/Off
Beep once for ON and beep twice for OFF
Learn Remote
Hold the OFF ▼ button while turning on the master switch
Transmitter
(Beep twice then press any handheld remote button)
6-hour safety
Press the ON ▲ button and OFF ▼ button simultaneously
ON
shutdown setup
(Beep once for ON, twice for OFF)
FUNCTIONS/OPERATION
Turning on the fireplace
1. Turn on the master switch and wait for a beep.
2. Press the ON button on the Command Center. Pilot will light and burner will come on
High setting.
Pilot Safety Lockout Function
1. If the pilot doesn’t light after sparking for 30 seconds, pilot trial lockout happens. The
LED on the Command Center flashes Green once every 2 seconds.
2. If the pilot flame is lost during normal operation, flame loss lockout happens. The LED
on the Command Center flashes Red-Green once every 2 seconds.
3. Turning off the master switch will reset the system.
Содержание 400DVBL
Страница 52: ...52 74D0010 2 3 4 5 6 7 illustrated parts lists firebox components ...
Страница 54: ...54 74D0010 illustrated parts lists 1 2 3 4 5 6 7 8 10 11 12 13 14 Standing Pilot Millivolt control 2T 2I 2C 8 ...
Страница 56: ...56 74D0010 illustrated parts lists SIGNATURE COMMAND SYSTEM 0009 SG parts 8 08 1 2 3 4 17 5 6 7 8 9 13 14 15 ...
Страница 64: ...64 74D0010 SEPTEMBER 2008 74D0010 Rev 10 MHSC 149 Cleveland Drive Paris Kentucky 40361 www mhsc com ...