74D0010
43
SIGNATURE COMMAND SYSTEM OPERATION INSTRUCTIONS
FUNCTIONS/OPERATION
(continued)
Flame Height Control
1. Press the ON button (on the Command Center) once to turn on the main burner with maximum
flame height.
2. Press the OFF button to decrease flame height. The first two presses will decrease the flame
height to medium and low.
3. The third press on OFF will turn off the main burner. In standing pilot configuration, the pilot
will stay; in intermittent pilot configuration, the pilot will be shut off.
Turning the Fireplace Off
There are three ways to turn the fireplace off.
1. Flip the master switch to the off (“O”) position
2. Press the OFF button to Medium, Low, then Off.
3. Hold the OFF button anytime for three seconds. This command of OFF will remember all last
settings before turning off. The next time the fireplace is turned on, all settings will resume.
Command Center Operations:
The following functions are available on the Command Center.
Function
Operation
Power Up
Flip the master switch to the ON ("_") position to power up the system
Fireplace ON
Press the ON ▲ button on the Command Center to turn the fireplace on
Fireplace OFF
Flip the master switch to the OFF ("o") position OR press the OFF ▼ button 3
times OR hold the OFF ▼ button 3 seconds
Flame Height Up
Press the ON ▲ button once to turn on the fireplace with maximum flame height
Flame Height Down
Press the OFF ▼ button to lower the flame height to Medium and Low
Self Diagnostics Chart:
The Command Center has a self-diagnostic LED enabling you to troubleshoot problems and poten
-
tially avoid a service call. Please refer to the charts below for indicator reference.
Fault
LED Indication
Conversion Cover Missing
One RED (1 time)
Spark Fail
Two RED (1 time)
No Sensor Signal
Three RED (1 time)
Pilot Lockout - trial
One GREEN, every 2 sec. (until manual reset)
Pilot Lockout - flame loss
One RED-GREEN, every 2 sec. (until manual reset)
Low Battery
One RED, every 10s (continuously)
No or Low Thermopile Power
Two RED, every 10s (continuously)
Learning
GREEN Flashes, every 1 sec. (for 10 sec.)
AC Power On
GREEN solid
Содержание 400DVBL
Страница 52: ...52 74D0010 2 3 4 5 6 7 illustrated parts lists firebox components ...
Страница 54: ...54 74D0010 illustrated parts lists 1 2 3 4 5 6 7 8 10 11 12 13 14 Standing Pilot Millivolt control 2T 2I 2C 8 ...
Страница 56: ...56 74D0010 illustrated parts lists SIGNATURE COMMAND SYSTEM 0009 SG parts 8 08 1 2 3 4 17 5 6 7 8 9 13 14 15 ...
Страница 64: ...64 74D0010 SEPTEMBER 2008 74D0010 Rev 10 MHSC 149 Cleveland Drive Paris Kentucky 40361 www mhsc com ...