FINAl INstAllAtIoN

RocK Wool plAceMeNt

1.  Place rock wool on burner to provide glowing embers. 

For best results, pull the rock wool apart into pieces 
the size of a dime or smaller. 

2.  Distribute one layer of rock wool to cover the  burner. 

Figure 60

3.  Place the logs on the burner. Refer to 

Log Placement 

below. Light unit and after 15 minutes, check burner 
flame and glow. Refer to 

Burner Flame

, Page 49. 

If the flame is blue and only in the center, turn off unit 
and  let  cool. After  unit  cools,  remove  logs.  If  the  back 
holes are clear, add more rock wool to the center of the 
burner. Replace logs and check flame again. Save left 
over rock wool to refresh when cleaning later. Too much 
rock  wool  can  disturb  the  flame  and  cause  sooting  on 
the glass or logs. 

FP2105
BDV base

Figure 60 - Placement of 
Rock Wool on Burner

Cover with 
Rock Wool 

Burner 

FP2105

W

ARNING

Do not use the entire bag of rock wool to 
cover the burner. this could cause the flame 
to burn poorly and may lead to sooting.

loG plAceMeNt

1.  Place rear log (#1) on grate assembly. Log should 

rest firmly on the two log mounting pins on the 
bars. 

Figure 61

2.  Place bottom left log (#2) on grate. Rest the back 

side of the log in the flat area of the rear log. 

Figure 

61 

3.  Place  bottom  right  log  (#3)  on  grate.  Rest  the 

back side of the log in the flat area of the rear log. 

Figure 61 

4.  Place the top log (#4) on the rear log. Nest the 

forked end of the  top left log into the fork or the 
rear log. Rest the narrow end of the top on the 
vertical grate bar.

 Figure 61 

lAVA RocK AND eMBeRs plAceMeNt

Sprinkle lava rock on the floor of the inner combustion 
chamber. Evenly distribute the rock. Do not pile the lava 
rock up in front of grate. Do not place lava rock on the 
burner. If desired, purchase optional embers to decorate 
the floor of the fireplace. 

LG607
DVB logs

Top Log #4

Bottom Left 
Log #2

Bottom 
Right 
Log #3

Log Mouting 
Pins

Flat Areas

Rear Log 
#1

Left Verti-
cal Grate 
Bar

Center Vertical 
Grate Bar

Right Vertical 
Grate Bar

LG607

Figure 61 -
Log Placement 
(300DVB & 400DVB Shown)

W

ARNING

Do  not  sprinkle  the  lava  rock  or  ember 
chunks on top of the burner. this may cause 
potential sooting, glass breakage and a fire 
hazard

Содержание 400DVB

Страница 1: ...l information consult a qualified installer service agency or the gas supplier This appliance may be installed in an aftermarket permanently located manufactured home USA only or mobile home where not...

Страница 2: ...nstallation 31 Electronic Pilot Ignition Wiring 32 Optional Fan Blower Systems Milli Volt 33 Operating Instructions Milli Volt 34 Lighting Pilot for the First Time 34 Lighting Pilot 35 Lighting Burner...

Страница 3: ...le for use with other gases unless a certified kit is used 2 For propane LP fireplace do not place propane LP supply tank s inside any structure Locate propane LP supply tank s outdoors To prevent per...

Страница 4: ...t has been exposed to or has been under water Immediately call a quali fied service technician to inspect the appliance and replace any part of the control system and any gas control which as been sub...

Страница 5: ...ures Hi Lo Knob Off Pilot On Knob On Off RS Switch Ignitor Blower Control Optional Remote Receiver FP2087 Figure 1 300 400 500 600DVB Fireplace Millivolt Control Shown Code Approval Direct Vent type a...

Страница 6: ...al Propane Natural Propane Max Btu hr Input 21 000 21 000 24 000 24 000 26 000 26 000 26 000 26 000 Min Btu hr Input 15 000 15 000 17 000 17 000 20 000 20 000 20 000 20 000 Orifice Size 43 54 41 53 40...

Страница 7: ...47Z zn B Inside Width 29M 32 36 42 C Glass Width 27 29 33 39 D Pipe Centerline 16Z x 18Z x 20Z x 23Z x E Rear Width 28 29 33 39 F Glass Height 18 20C 20C 20C G Chassis Height 33M 37Z x 37Z x 37Z x H D...

Страница 8: ...lled directly on carpeting tile or other combustible material other than wood flooring the firebox shall be installed on a metal or wood panel extending the full width and depth of the enclosure WARNI...

Страница 9: ...enting section found in this manual for allowable venting configurations These units can be installed in a bedroom See National Fuel Gas Code ANSI Z233 1 NFPA 54 current edition the Uniform Mechanical...

Страница 10: ...ooring the appliance shall be installed on a metal wood or noncombustible material panel extending full width and depth of the appliance 71 Minimum 11 Minimum 12 Min Min 4 From Either Side Wall FP2248...

Страница 11: ...crete screws to secure fireplace to the floor Use four 4 screws to attach fireplace to framing The side nailing flanges are 1 2 or 5 8 to accommodate different wall thickness FP2094 secure fireplace F...

Страница 12: ...other than permitted by these instructions Finishing Material NOTE Any remote wiring i e remote control wall switch and optional fan must be done prior to final finishing to avoid costly reconstructio...

Страница 13: ...nd bottom until the flue penetrates the outside wall A minimum 1 clearance all around the flue is acceptable at this point of penetration If vertical rise is 7Z x feet or higher when top venting the c...

Страница 14: ...the cover and gasket Figure 8 4 Remove six 6 screws securing the flue pipe to the back of the intake box and remove the pipe and gasket Figure 9 5 Replace flue pipe to top of firebox Ensure the gaske...

Страница 15: ...lbows maximum or a combination of 90 and 45 elbows up to a maximum of 270 For two story applications firestops are required at each floor level If an offset is needed in the attic additional pipe and...

Страница 16: ...14 mm minimum J Clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance 12 305 mm minimum K Clearance to a mechanical air supply inlet 6 1829 mm min...

Страница 17: ...e the height of the center of the horizontal vent pipe exit ing through the outer wall Using this dimension on the Sidewall Vent Graph below locate the point intersecting with the slanted graph line 2...

Страница 18: ...hemmed and will snap into the collar s tabs Attach Simpson s DirectVent Pro by fully inserting into the collar and securing with self tapping screws The screws shall only penetrate the flue outer wall...

Страница 19: ...18 5 Slide the firestop over the vent pipe before connecting the horizontal run to the vent cap Figure 19 6 The termination should overlap the flue a minimum of 1Z v Apply silicone to the outer pipe...

Страница 20: ...izes the number of offsets and horizontal vent length The horizontal vent run refers to the total length of vent pipe from the flue collar of the fireplace or the top of the Transition Elbow to the fa...

Страница 21: ...lus B must not be greater than 17 5 2 m The maximum number of 45 elbows permitted per side wall installation is two 2 These elbows can be installed in either the vertical or horizontal run For each 45...

Страница 22: ...snorkel Install drain pipe Install window well not supplied Refill hole with 12 of coarse gravel leaving a clearance of approximately 4 below snorkel Figure 26 3 Install vent system 4 Ensure a watert...

Страница 23: ...learance to combustibles on all sides of the pipe FP1183 max height 40 Maximum Height 8 Minimum Height 10 Maximum Support Straps Every 3 Sup port Straps Every 3 Support Straps Every 3 Fp1183 40 Maximu...

Страница 24: ...ling locat ing hole in the ceiling Mark the center point where the vent will penetrate the roof Drill a small locating hole at this point flat ceiling installation 1 Cut a 9Z x 241 mm square hole in t...

Страница 25: ...sulation Cathedral Ceiling INstallation 1 Remove shingles or other roof covering as necessary to cut the rectangular hole for the support box Mark the outline of the cathedral ceil ing support box on...

Страница 26: ...place and secure with screws 2 Slide the small gear clamp over the inner flexible vent pipe and push out of the way 3 Pull and extend the inner flexible vent 4 Slide the inner vent onto the adapter c...

Страница 27: ...d terminations and accessories installed per the installation instructions and Figure 36 E Installing flexible venting to horizontal termination assemblies 1 Connect the 4 flexible vent to the horizon...

Страница 28: ...ign certified equipment shutoff valve with 1 8 NPT tap is an acceptable alternative to test gauge connection Purchase the CSA design certified equipment shutoff valve from your dealer For propane LP c...

Страница 29: ...the gas to the fireplace Check your building codes for any special requirements for locating equipment shutoff valve to fireplaces Apply pipe joint sealant lightly to male threads This will prevent e...

Страница 30: ...fter taking pressure reading be sure and turn captured screw clockwise firmly to reseal Do not over torque Check test points for gas leaks Electrical Wiring This fireplace will work without any electr...

Страница 31: ...not extend beyond the wall switch wire length provided NOTE Extended lengths of wire may cause the fireplace not to function properly Longer length of wire is permitted if the wire is made out of lar...

Страница 32: ...nse Ignition Module EV1 EV2 24V 6 24V GND 5 PV 3 MV PV 2 MV 1 GND BURNER 4 SENSE 8 SPARK 9 FP2100 BDV pilot wiring Figure 43 Remote Wall Switch Wiring Diagram Remote Wall Switch Position the wall swit...

Страница 33: ...system requires that 110 120 VAC to be wired to the factory installed junction box before the fireplace is permanently installed Figure 44 TAN TAN WHITE GREEN BLACK BLACK BLACK Receptacle Junction Bo...

Страница 34: ...qualified service technician Force or attempted repair may result in a fire or explosion D Do not use this appliance if any part of it has been under water Immediately call a qualified service techni...

Страница 35: ...t period of time when the magnet is closed it is possible to start the lighting operation The gas control knob is designed to be operated by hand DO NOT use any tools during this operation Damaged kno...

Страница 36: ...lace This switch allows you to turn on and to turn off the main burner without using the gas valve knob Make sure the button is in the ON position to light the main burner Figure 46 Lighting the burne...

Страница 37: ...the control system and any gas control that has been under water OPERATING INSTRUCTIONS ELECTRONIC ON OFF PILOT LO HI FP2102 BDV electronic valve Figure 50 Electronic Gas Valve Lighting electronic ign...

Страница 38: ...w clockwise firmly to reseal Do not over torque Check test points for gas leaks Figure 51 Signature Command Valve FP1909a signature command valve alternate view 8 08 Pressure Inlet Pilot Adjust ment S...

Страница 39: ...PTIONAL AUX PLUG IN CONNECTOR ON HI OFF LO LED IGNITER SPARKER SENSING RED THERMOPILE BLACK THERMOPILE PILOT GAS TUBING PILOT CONTROL BOX PLUG IN CONNECTOR CONTROL BOX TO COMMAND CENTER PLUG IN CONNEC...

Страница 40: ...2 Remove glass frame by releasing the two 2 latches 500 and 600 models have three 3 latches below the firebox open ing and lifting glass frame up and away from unit 3 Use the supplied Velcro on the bl...

Страница 41: ...n Control Box AC Box Figure 56 Connect AC Box to Control Box NOTE The black and white wires on the AC box wiring harness are marked Blower Light and Aux It is important to use the wires marked Blower...

Страница 42: ...r s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department C Use only your finger to push in the master switch Never use tools If the switch will n...

Страница 43: ...our Homeowner s Manual bag into the command center box Make sure the batteries orientation match 5 Press the master switch to the ON position Within eight 8 seconds it will beep once This indicates th...

Страница 44: ...Auxiliary AC Outputs Transmitter Optional RFSC RTSC RMSC Three Flame Height Settings X X X Low battery Indication for Transmitter X X X Child Proof Lock out X X X LCD Backlight X X X Security Codes X...

Страница 45: ...tion can begin Use paper clip to depress button One beep for RF receiver ON or two beeps for RF receiver OFF will be given as confirmation 2 After the RF receiver is on holding the OFF button on the C...

Страница 46: ...ter switch to the off O position 2 Press the OFF button to Medium Low then Off 3 Hold the OFF button anytime for three seconds This command of OFF will remember all last settings before turning off Th...

Страница 47: ...frame up until it clears three tabs on top of fireplace 3 Set glass frame aside FP2104 BDV remove glass FP2104 Figure 59 Remove Glass Frame Glass Frame Three Tabs Clamps Two 2 on 300 400 Units Three...

Страница 48: ...and may lead to sooting log placement 1 Place rear log 1 on grate assembly Log should rest firmly on the two log mounting pins on the bars Figure 61 2 Place bottom left log 2 on grate Rest the back si...

Страница 49: ...hermopile one engulfing the thermocouple and the other reaching to the main burner burner Inspect area around the injector Remove any lint or foreign material with a brush or vacuum FP1943 pilot flame...

Страница 50: ...als may be used Handle glass door with care to avoid striking or scratching it on hard objects To clean glass door follow Glass Removal procedure outlined in the Final Installation section Film deposi...

Страница 51: ...the thermocouple connec tion at the gas valve is fully inserted and tight Disconnect the thermocouple from the valve place one millivolt lead wire on the tip of the thermocouple and the other meter le...

Страница 52: ...ust the pilot flame for maximum flame impingement on thermocouple A Check for flue product leak Replace defective pipe section B Check horizontal venting piping is running upward 1 4 per foot Do not r...

Страница 53: ...hrough Battery polarity wrong LED on the Command Center does not show solid green The 5 pin connector on the AC board broken or bent AC plug is plugged to AC mains Battery voltage low Using battery Ch...

Страница 54: ...DVB Series Direct Vent Gas Fireplace 54 54D0701 REPLACEMENT PARTS 1 2 3 5 6 7 8 10 4 9 540701 DVB parts FIREBOX COMPONENTS...

Страница 55: ...ard Firebrick Left Cr 1 26D7096 26D7103 26D7103 26D7103 10 Blower Motor 1 54D0281 26D0748 26D0748 26D0748 Accessories Field Installed Options 2 Brass Louver 1 L30BR L32BR L36BR L42BR 2 Pewter Louver 1...

Страница 56: ...DVB Series Direct Vent Gas Fireplace 56 54D0701 REPLACEMENT PARTS STANDING PILOT MILLIVOLT CONTROL 1 2C 2I 2T 2 4 5 6 3 8 9 7 10 11 12 13 14 540701 DVB millivolt parts...

Страница 57: ...41D0048 41D0048 41D0048 41D0048 41D0048 6 Piezo Igniter 1 14D0503 14D0503 14D0503 14D0503 14D0503 14D0503 14D0503 14D0503 7 Injector 1 62D3006 20H3146 62D3004 20H3143 20H3145 57D0210 20H3145 57D0210...

Страница 58: ...VB Series Direct Vent Gas Fireplace 58 54D0701 REPLACEMENT PARTS ELECTRONIC IGNTION 1 2 4 5 6 3 8 9 7 10 11 L O HI 24V 6 24V GND 5 PV 3 MV PV 2 MV 1 GND BURNER 4 SENSE 8 SPARK 9 540701 DVB elect parts...

Страница 59: ...toff Valve 1 23D6046 23D6046 23D6046 23D6046 23D6046 23D6046 23D6046 23D6046 5 Rocker Switch 1 41D0048 41D0048 41D0048 41D0048 41D0048 41D0048 41D0048 41D0048 6 Injector 1 62D3006 20H3146 62D3004 20H3...

Страница 60: ...DVB Series Direct Vent Gas Fireplace 60 54D0701 REPLACEMENT PARTS 1 2 3 4 17 5 6 7 8 9 13 14 15 540701 SC parts SIGNATURE COMMAND SYSTEM...

Страница 61: ...10 8 Burner Assembly 1 54D0200 54D0200 54D0001 54D0001 54D0329 54D0329 54D0329 54D0329 9 Venturi 1 45D0600 45D0600 45D0600 45D0600 45D0600 45D0600 45D0600 45D0600 10 Wire Valve Control not shown 1 80D...

Страница 62: ...DVB Series Direct Vent Gas Fireplace 62 54D0701 REPLACEMENT PARTS VENT COMPONENTS HOT 1 2 3 4 5 6 9 7 8 11 10 540701 DVB vent components...

Страница 63: ...rtical Termination Cap 46DVA VC 980 4DT VC 3 6 6 Pipe Length galvanized 46DVA 06 908 4DT 06 3 6 9 Pipe Length galvanized 46DVA 09 907 4DT 09 3 6 12 Pipe Length galvanized 46DVA 12 906 4DT 1 3 6 24 Pip...

Страница 64: ...LOGS 1 2 3 4 540701 DVB log parts Ref Description Qty 300DVB 400DVB 500DVB 600DVB 1 Rear Log 1 54D0122 54D0117 54D0331 54D0331 2 Left Log 1 54D0123 54D0118 54D0358 54D0358 3 Right Log 1 54D0124 54D01...

Страница 65: ...s less than seven 7 feet above finished grade in the area of the venting including but not limited to decks and porches the following requirements shall be satisfied 1 INSTALLATION OF CARBON MONOXIDE...

Страница 66: ...part for residential purposes c MANUFACTURER REQUIREMENTS GAS EQUIPMENT VENTING SYSTEM PROVIDED When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting...

Страница 67: ...ed Lifetime Warranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 firebox burner assem...

Страница 68: ...Efficiency Ratings Model EnerGuide Ratings Fireplace Efficiency 300DVBNV 57 9 300DVBPV 53 8 300DVBNE 61 8 300DVBPE 55 7 400DVBNV 58 4 400DVBPV 58 5 400DVBNE 61 1 400DVBPE 60 7 500DVBNV 58 7 500DVBPV 5...

Отзывы: