DVB Series Direct Vent Gas Fireplace
54D0701
41
optIoNAl FAN BloWeR systeM
7. Secure the AC box to the control box using
screw provided.
Figure 56
8. Plug in wiring harness to the back of AC box.
9. Connect the blower according to the wiring
diagram.
Figure 57
Note:
Be sure to use the
wires marked ‘Blower’.
10. Replace glass frame .
11. Plug the AC box plug to the junction box.
Fig-
ure 57
12. To test blower operation. Turn the fireplace
on. Turn blower on. The blower should turn on
within five (5) minutes. Refer to the operating
instructions on Signature Command remote
control for complete operation instructions.
Finishing
Re-install the lower access panel.
FP1916
AC box
8/08
Screw
Guiding Block
Connector Hole
Connector Pin
control Box
Ac Box
Figure 56 -
Connect AC Box to Control Box
N
ote
the black and white wires on the Ac box
wiring harness are marked ‘Blower’, ‘light’
and ‘Aux’. It is important to use the wires
marked ‘Blower’ or the contoll will not work
correctly.
W
ARNING
electrical Grounding Instructions: this
appliance is equipped with a three-prong
(grounding) plug for your protection
against shock hazard and should be
plugged directly into a properly grounded
three-prong receptacle.
W
ARNING
electrical connections should only
be performed by a qualified licensed
electrician. Main power supply must
be turned off before connecting the fan
to the main electrical power supply or
performing service.
To Junction Box
In Fireplace
WHITE
BLACK
WHITE
BLACK
BLACK
WHITE
GREEN
Connector
Pin To Contro l Box
{
{
Optional
Light
Optional
AUX
Blower
(300 W
Max)
FP2103
AC fan wiring
Figure 57 -
Blower Wiring Diagram
FP2103
control Box
optional
Ac Box