Majestic fireplaces UV36RN Скачать руководство пользователя страница 7

7

UV36RN/RP Vent-Free Gas Fireplaces

20007436

Installation & Operating Instructions

Locating the Fireplace

Figure 3 shows some of the many ways your fireplace 
may be installed. Consider the traffic pattern in your 
room and the location of doors and windows.  Moving 
air from ceiling fans, open doors and hot air grilles may 
cause the flames to soot.  If a disturbance is found that 
affects the flames, it must be eliminated by turning off 
the ceiling fan, closing the door or closing/moving the 
hot air register.  A corner location may be best where 
space is limited.
Your fireplace weighs no more than some of your fine 
furniture.  If the fireplace is located near a load bearing 
wall, additional supports to the foundation will not be 
necessary.

NOTE: 

Heavy facings such as brick, stone, etc., may 

require additional foundation support.

NOTE: Although this unit may be installed on com-
bustible surfaces, it must not be installed on carpet 
or vinyl.

The clearances to sidewalls and ceiling that are shown 
in Figures 5, 6a, 6b and 7 must be considered when 
choosing the location for the fireplace.

LU584-1

Locating unit

2/4/99   djt

Partial Room 

Projection

Corner

Full Room 
Projection

Room 
Divider

Flush

LU584-1

Fig. 3

  Locating the fireplace.

Gas Line

The gas line must be installed by a licensed gas line 
installer before framing in the fireplace.

Drafts

Do not locate the fireplace in high traffic areas or areas 
exposed to high drafts and winds. Locate the fireplace 
away from furniture and draperies.

Fan Kit - Optional

If the construction of your fireplace is with a full outer 
casing and full bottom pan, use Blower Kit BL-4 or 
FK12.
If the construction of your fireplace is with two sheet 
metal legs supporting the combustion chamber at the 
back, use Blower Kit BL-3. The variable speed control, 
SCVS, is included with the BL-3.
Optional variable speed control, Model SCVS, may be 
used with the Blower Kit BL-4. 

Electrical Services

All optional fan kits are equipped with a 120V, 60Hz 
blower, less than 12 amps.
A 120V outlet, Part no. EB-1, is needed in the fireplace 
in order to plug in the optional blower accessory.  The 
blower is equipped with a standard 3-prong electrical 
plug.

Installation Tip:

 The blower will be easier to install if 

done at time of appliance installation.

Framing Clearances

The fireplace may be placed directly on a combustible 
floor, against a combustible wall at marked clearances 
or on a raised wooden platform.
If the fireplace is to be installed on a raised wooden 
platform, the platform must be a continuous level sur-
face.
The fireplace must be secured in place so it cannot shift 
positions.  The nailing flanges on the sides of the fire-
box make securing it to the framing easy.  They were 
designed to allow the installation of 1/2” wallboard or 
plywood flush with the face of the fireplace.
Only the header (Fig. 4) may rest on the standoffs on 
top of the firebox.  Framing must rest on top of stand-
offs.
When the fireplace is installed over carpeting, vinyl tile 
or any combustible material other than wood flooring, 
it must be installed on a metal or wood panel extend-
ing its full width and depth.  Alternatively - the carpet-
ing, vinyl tile, etc., may be removed from beneath the 
fireplace before installing.

Combustible materials must not be installed over or 
touch the black front surface of the fireplace.

Содержание UV36RN

Страница 1: ...use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas sup plier call the re department Installa...

Страница 2: ...rts 19 Warranty 21 This book contains your operating and installation instructions and should be kept in a safe place For you to realize all the advantages and use of the reliable service that has bee...

Страница 3: ...r ammable material on or near the appliance This appliance must only be used with pressures at the inlet as shown in Table 1 Page 11 in installation instructions The installation must conform with loc...

Страница 4: ...epth 7436 UV36RN rp Specs 11 4 03 djt 35 33 1 2 3 7 8 11 8 Outside Air Access Gas Line Access Not used on this model Gas Line Access 3 7 8 8 Gas Line Electrical Access Gas Line Access Not used on this...

Страница 5: ...pliances in the space Gas range_________________ BTU Hr Vented gas heater __________ BTU Hr Gas replace logs___________ BTU Hr Other gas appliances _____ BTU Hr Total _____ BTU Hr Example Gas range 60...

Страница 6: ...oors or spaces open to the outdoors These spaces include attics and crawl spaces Follow the National Fuel Gas Code NFPA 54 ANSI Z223 1 Section 5 3 Air for Combustion and Ventilation for required size...

Страница 7: ...full outer casing and full bottom pan use Blower Kit BL 4 or FK12 If the construction of your replace is with two sheet metal legs supporting the combustion chamber at the back use Blower Kit BL 3 Th...

Страница 8: ...st boards etc is 9 Combustible material projecting 6 a mantel shelf for example requires a minimum clearance of 12 above the replace opening Required clearance varies with the amount of projection Fig...

Страница 9: ...F THE CANOPY UNDER THE LOOSENED SCREWS THEN RETIGHTEN THE SCREWS TO SECURE THE CANOPY Fig 5a Step 2 Install the Firebox Install the rebox into the framed opening by setting it directly in front of the...

Страница 10: ...ater s rating plate If the gas type indicated on the plate is not your type of gas supply DO NOT INSTALL Contact your dealer for proper model Gas Piping The gas supply line must be of an ad equate siz...

Страница 11: ...determine the size of the branch gas line from the main gas line to the replace enter the tables below for iron pipe or copper tubing using the distance from the gas meter or second stage regulator t...

Страница 12: ...nly on top of the front burner port area Equally space embers one layer thick Do not pile ember material over one layer thick as this does not enhance the ember appearance or improve the log set perfo...

Страница 13: ...B B A T148 attach wires 11 5 03 djt A Existing valve wiring Do not tamper with B Remote receiver wires red or white on either side Fig 12 Attach receiver wires to outer two terminals on valve Installa...

Страница 14: ...tructions 1 STOP Read the safety information above before proceed ing 2 Refer to Figure 16 To turn off the gas supply depress the knob slightly and turn clockwise to the OFF position 3 Wait ve 5 minut...

Страница 15: ...hutter Settings Model A UV36RN 0 125 UV36RP 0 375 T134 Fig 23 Air shutter settings Finishing the Fireplace There are a wide variety of nishing materials avail able for your replace from formal wall tr...

Страница 16: ...d combination of ame aesthetics and heat output Fig 24 Finishing options T146 finishing 11 5 03 djt Wallboard with Marble Slate or Tile Facing Brick or Stone Facing Wallboard with Facing and Mantel Fi...

Страница 17: ...acuum cleaner to carefully remove dust and loose par ticles from the base logs and from around the burner Gloves are recommended when handling the logs Use extreme caution when cleaning around the pil...

Страница 18: ...clogged Clean burner ori ce Control knob not in ON position Turn control knob to ON position 4 Heater shuts off on ODS Not enough fresh air is available Open window Low gas pressure Contact your gas s...

Страница 19: ...s at any time without notice 7436 UV36RN UV36RP Ref Description UV36RN UV36RP 1 Grate Assembly 78442 78442 2 Side De ector 78443 78443 3 Support Channel 78439 78439 4 Air Scoop 78445 78445 5a Valve Na...

Страница 20: ...78596 78596 14 Mini Rocker Switch PCOA049 PCOA049 15 Knob Extension On Off 3 77958 77958 16 Knob Extension Hi Lo 3 77959 77959 17 Embers Platinum Bag 78037 78037 18 Lava Gravel Assy 68688 68688 19 Log...

Страница 21: ...21 UV36RN RP Vent Free Gas Fireplaces 20007436...

Страница 22: ...22 UV36RN RP Vent Free Gas Fireplaces 20007436...

Страница 23: ...ction the damage is found to be the fault of the manufacturer repairs will be authorized at no charge to the customer parts and or labor Any part and or component replaced under the provisions of this...

Страница 24: ...2695 Meadowvale Blvd Mississauga Ontario Canada L5N 8A3 800 668 5323 www cfmcorp com CFM Corporation...

Отзывы: