Majestic fireplaces UV36RN Скачать руководство пользователя страница 3

3

UV36RN/RP Vent-Free Gas Fireplaces

20007436

Important Information

INSTALLER:

 Please leave these instructions with the 

owner.

OWNER:

  Please retain these instructions for future 

reference.

IMPORTANT: READ THESE INSTRUCTIONS CARE-
FULLY BEFORE OPERATING.

• 

DO NOT

 use this heater if any part of it has been under 

water. Immediately call a qualified technician to inspect the ap-
pliance and replace any part of the control system and any gas 
control which has been under water.

• 

This appliance may be installed in an after-market* manu-

factured “mobile” home where not prohibited by state or local 
codes.

*After-market:  Completion of sale, not for purpose of re-sale from the 
manufacturer.

• 

Children and adults should be alerted to the hazard of high 

surface temperature and should stay away to avoid burns or 
clothing ignition.

• 

Although your gas logs are very realistic in appearance, 

it is not a real wood-burning fireplace and must not be 
used for burning solid fuel.

• 

To avoid irreparable damage to the appliance or personal 

injury; matches, paper, garbage or any other material must not 
be placed or thrown on top of the logs or into the flames.

• 

To avoid personal injury, do not touch hot surfaces when 

the appliance is operating.

• 

Close supervision is necessary when the appliance is 

being operated near children.

• 

Do not use to cook food.

• 

This appliance is intended to be used only for supplemen-

tal heat.  

Do not use it routinely as a primary heat source.

  

Continuous operation could produce excessive humidity 
depending on construction characteristics and outdoor tempera-
tures (below 20°F).  Over time, this could cause condensation 
to form and damage wall structures and exterior paint.

• 

An unvented room heater having an input rating of more than 

10,000 btu per hour shall not be installed in a bedroom or bath-
room.

NOTES

• 

Due to high temperatures, the appliance should be lo-

cated out of traffic and away from furniture and draperies.

• 

Installation and repair must be done by a qualified service 

person or gas appliance installer.

• 

A fireplace screen must be in place when the appliance is 

operating.  On models with movable screens, the screens must 
be closed when the fireplace is operating.

• 

The appliance must be inspected before use and at least 

annually by a professional service person. More frequent 
cleaning may be required due to excessive lint from carpeting, 
bedding material, dust and pet hair, etc. It is important that the 
control compartment, burners and circulating air passageways 
of the appliance be kept clean.

• 

DO NOT place clothing or other flammable material on or 

near the appliance.

• 

This appliance must only be used with pressures at the inlet 

as shown in Table 1, Page 11 in installation instructions.

• 

The installation must conform with local codes or, in the 

absence of local codes, with the NATIONAL FUEL GAS CODE, 
ANSI Z223/NFPA 54, latest edition.

• 

Any safety screen or guard removed for servicing an appli-

ance must be replaced prior to operating the heater.

• 

The appliance and its appliance main gas shut-off valve must 

be disconnected from the gas supply piping system during any 
pressure testing of that system at test pressures in excess of   
1/2 psig (3.5 kpa).

• 

The appliance must be isolated from the gas supply piping 

system by closing its equipment shut-off valve during any test-
ing of the gas supply piping system at test pressures equal to or 
less than 1/2 psig (3.5 kpa).

• 

DO NOT

 use this heater in recreational vehicles, bedrooms 

or bathrooms.

• 

If this is the ONLY gas appliance, we recommend a 

minimum 200 pound cylinder with a fill gauge.  Use of a 100 
pound cylinder is not recommended.  Other household gas 
appliances may require the tank size to be larger.  Do not 
operate the vent-free heater if the fuel level in the propane 
tank is below 1/4 full.

• 

Use only with two-stage regulator.

WARNING:  During manufacturing, fabricating and ship-
ping, various components of this appliance are treated 
with certain oils, films or bonding agents.  These chemi-
cals are not harmful but may produce annoying smoke 
and smells as they are burned off during the initial 
operation of the appliance, possibly causing headaches 
and eye/lung irritation.  This is a normal and temporary 
occurrence.

WARNING:  Do not use a blower insert, heat exchanger 
insert or other accessory not approved for use with this 
heater.

WARNING:  If the area in which the heater may be operat-
ed is smaller than that defined as an unconfined space or 
if the building is of unusually tight construction, provide 
adequate combustion and ventilation air by one of the 
methods described in the National Fuel Gas code, ANSI 
Z223.1/NFPA 54, section 5.3 or applicable local codes.

This heater shall not be installed in a confined space or 
unusually tight construction unless provisions are pro-
vided for adequate combustion and ventilation air.

WARNING: Any change to this heater or its controls can 
be dangerous.
This appliance is only for use with the type of gas indi-
cated on the rating plate. This appliance is not convertible 
for use with other gases.

This appliance may be  installed  in an aftermarket, per-
manently located, manufactured (mobile) home, where 
not prohibited by local codes.

WARNING: Do not install televisions or other elec-
tronic devices above this fireplace unless approved 
by the electronics manufacturer.

Содержание UV36RN

Страница 1: ...use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas sup plier call the re department Installa...

Страница 2: ...rts 19 Warranty 21 This book contains your operating and installation instructions and should be kept in a safe place For you to realize all the advantages and use of the reliable service that has bee...

Страница 3: ...r ammable material on or near the appliance This appliance must only be used with pressures at the inlet as shown in Table 1 Page 11 in installation instructions The installation must conform with loc...

Страница 4: ...epth 7436 UV36RN rp Specs 11 4 03 djt 35 33 1 2 3 7 8 11 8 Outside Air Access Gas Line Access Not used on this model Gas Line Access 3 7 8 8 Gas Line Electrical Access Gas Line Access Not used on this...

Страница 5: ...pliances in the space Gas range_________________ BTU Hr Vented gas heater __________ BTU Hr Gas replace logs___________ BTU Hr Other gas appliances _____ BTU Hr Total _____ BTU Hr Example Gas range 60...

Страница 6: ...oors or spaces open to the outdoors These spaces include attics and crawl spaces Follow the National Fuel Gas Code NFPA 54 ANSI Z223 1 Section 5 3 Air for Combustion and Ventilation for required size...

Страница 7: ...full outer casing and full bottom pan use Blower Kit BL 4 or FK12 If the construction of your replace is with two sheet metal legs supporting the combustion chamber at the back use Blower Kit BL 3 Th...

Страница 8: ...st boards etc is 9 Combustible material projecting 6 a mantel shelf for example requires a minimum clearance of 12 above the replace opening Required clearance varies with the amount of projection Fig...

Страница 9: ...F THE CANOPY UNDER THE LOOSENED SCREWS THEN RETIGHTEN THE SCREWS TO SECURE THE CANOPY Fig 5a Step 2 Install the Firebox Install the rebox into the framed opening by setting it directly in front of the...

Страница 10: ...ater s rating plate If the gas type indicated on the plate is not your type of gas supply DO NOT INSTALL Contact your dealer for proper model Gas Piping The gas supply line must be of an ad equate siz...

Страница 11: ...determine the size of the branch gas line from the main gas line to the replace enter the tables below for iron pipe or copper tubing using the distance from the gas meter or second stage regulator t...

Страница 12: ...nly on top of the front burner port area Equally space embers one layer thick Do not pile ember material over one layer thick as this does not enhance the ember appearance or improve the log set perfo...

Страница 13: ...B B A T148 attach wires 11 5 03 djt A Existing valve wiring Do not tamper with B Remote receiver wires red or white on either side Fig 12 Attach receiver wires to outer two terminals on valve Installa...

Страница 14: ...tructions 1 STOP Read the safety information above before proceed ing 2 Refer to Figure 16 To turn off the gas supply depress the knob slightly and turn clockwise to the OFF position 3 Wait ve 5 minut...

Страница 15: ...hutter Settings Model A UV36RN 0 125 UV36RP 0 375 T134 Fig 23 Air shutter settings Finishing the Fireplace There are a wide variety of nishing materials avail able for your replace from formal wall tr...

Страница 16: ...d combination of ame aesthetics and heat output Fig 24 Finishing options T146 finishing 11 5 03 djt Wallboard with Marble Slate or Tile Facing Brick or Stone Facing Wallboard with Facing and Mantel Fi...

Страница 17: ...acuum cleaner to carefully remove dust and loose par ticles from the base logs and from around the burner Gloves are recommended when handling the logs Use extreme caution when cleaning around the pil...

Страница 18: ...clogged Clean burner ori ce Control knob not in ON position Turn control knob to ON position 4 Heater shuts off on ODS Not enough fresh air is available Open window Low gas pressure Contact your gas s...

Страница 19: ...s at any time without notice 7436 UV36RN UV36RP Ref Description UV36RN UV36RP 1 Grate Assembly 78442 78442 2 Side De ector 78443 78443 3 Support Channel 78439 78439 4 Air Scoop 78445 78445 5a Valve Na...

Страница 20: ...78596 78596 14 Mini Rocker Switch PCOA049 PCOA049 15 Knob Extension On Off 3 77958 77958 16 Knob Extension Hi Lo 3 77959 77959 17 Embers Platinum Bag 78037 78037 18 Lava Gravel Assy 68688 68688 19 Log...

Страница 21: ...21 UV36RN RP Vent Free Gas Fireplaces 20007436...

Страница 22: ...22 UV36RN RP Vent Free Gas Fireplaces 20007436...

Страница 23: ...ction the damage is found to be the fault of the manufacturer repairs will be authorized at no charge to the customer parts and or labor Any part and or component replaced under the provisions of this...

Страница 24: ...2695 Meadowvale Blvd Mississauga Ontario Canada L5N 8A3 800 668 5323 www cfmcorp com CFM Corporation...

Отзывы: