background image

BASIC WARRANTY

 

CFM Corporation (hereinafter referred to collectively as the Company) 
warrants that your new Vermont Castings or Majestic Gas Fireplace/
Stove is free from manufacturing and material defects for a period of 
one year from the date of purchase, subject to the following conditions 
and limitations.

EXTENDED LIFETIME WARRANTY

 

The  heat  exchanger,  where  applicable,  and  combustion  chamber 
of every Vermont Castings or Majestic gas product is warranted for 
life against through wall perforation. All appliances equipped with an 
Insta-Flame  Ceramic  Burner  have  limited  lifetime  coverage  on  the 
ceramic burner plaque. Warrantees are made to the original owner 
subject to proof of purchase and the conditions and limitations listed 
on this Warranty Document

COMPONENT WARRANTY

CAST IRON: All external and internal cast iron parts are warranted for a 
period of three years.

 

Note

: On porcelain enamel finished external parts and accessories The 

Company offers no Warranty on chipping of enamel surfaces. Inspect 
all product prior to accepting it for any damage to the enamel.

 

 The salt air environment of coastal areas or a high humidity environment 
can be corrosive to the porcelain enamel finish. These conditions can 
cause rusting of the cast iron beneath the porcelain enamel finish, 
which will cause the finish to flake off.

 

Dye lot variations with replacement parts and/or accessories can occur 
and are not covered by warranty.

GLASS DOORS: Glass doors are covered for a period of one year. 
Glass doors are not warranted for breakage due to misuse or accident.  
Glass doors are not covered for discoloration or burned in stains due to 
environmental issues, or improper cleaning and maintenance.
BRASS PLATED PARTS AND ACCESSORIES: Brass parts should be 
cleaned with Lemon oil only.

 

Brass cleaners cannot be used.  Mortar 

mix and masonry cleaners may corrode the brass finish.  The Company 
will not be responsible for, nor will it warrant any brass parts which are 
damaged by external chemicals or down draft conditions.
GAS VALVES: Gas valves are covered for a period of one year
ELECTRONIC  AND  MECHANICAL  COMPONENTS:  Electronic  and 
mechanical components of the burner assembly are covered for one year. 
All steel tube burners are warranted for one year.
ACCESSORIES:  Unless  otherwise  noted  all  components  and  CFM 
Corporation company supplied accessories are covered for a period of 
one year.

CONDITIONS AND LIMITATIONS

•  This new Vermont Castings or Majestic product must be installed by 

a competent, authorized, service contractor. A licensed technician, as 
prescribed by the local jurisdiction must perform any installation/service 
work. It must be installed and operated at all times in accordance with 
the Installation and Operating instructions furnished with the product. 
Any alteration, willful abuse, accident, or misuse of the product shall 
nullify this warranty.

•  This warranty is non-transferable, and is made to the original owner, 

provided that the purchase was made through an authorized supplier 
of the Company.

•  The customer must pay for any Authorized Dealer in-home travel fees 

or service charges for in-home repair work. It is the dealers option 
whether the repair work will be done in the customer’s home or in the 
dealer’s shop.

•  If upon inspection, the damage is found to be the fault of the manufacturer, 

repairs will be authorized at no charge to the customer parts and/or 
labor.  

•  Any  part  and/or  component  replaced  under  the  provisions  of  this 

warranty is covered for six months or the remainder of the original 
warranty, whichever is longest.

•  This warranty is limited to the repair of or replacement of part(s) found 

to be defective in material or workmanship, provided that such part(s) 
have been subjected to normal conditions of use and service, after 
said defect is confirmed by the Company’s inspection.

•  The  company  may,  at  its  discretion,  fully  discharge  all  obligations 

with respect to this warranty by refunding the wholesale price of the 
defective part(s)

•  Any installation, labor, construction, transportation, or other related 

costs/expenses  arising  from  defective  part(s),  repair,  replacement, 
or otherwise of same, will not be covered by this warranty, nor shall 
the Company assume responsibility for same. Further, the Company 
will not be responsible for any incidental, indirect, or consequential 
damages except as provided by law.

• 

SOME  STATES  DO  NOT  ALLOW  FOR  THE  EXCLUSION  OR 
LIMITATIONS OF INCIDENTAL AND CONSEQUENTIAL DAMAGES 
OR  LIMITATIONS  ON  HOW  LONG  AN  IMPLIED  WARRANTY 
LASTS, SO THE ABOVE LIMITATIONS MAY NOT APPLY TO YOUR 
CIRCUMSTANCES.    THIS  WARRANTY  GIVES  YOU  SPECIFIC 
RIGHTS AND YOU MAY HAVE OTHER RIGHTS WHICH VARY FROM 
STATE TO STATE. 

•  All other warranties-expressed or implied- with respect to the product, 

its components and accessories, or any obligations/liabilities on the 
part of the Company are hereby expressly excluded.

•  The  Company  neither  assumes,  nor  authorizes  any  third  party  to 

assume on its behalf, any other liabilities with respect to the sale of 
this Vermont Castings, Majestic product

•  The warranties as outlined within this document do not apply to chimney 

components or other non Vermont Castings, Majestic accessories used 
in conjunction with the installation of this product..

•  Damage to the unit while in transit is not covered by this warranty but 

is  subject  to  claim  against  the  common  carrier.  Contact  the  dealer 
from whom you purchased your fireplace/stove (do not operate the 
appliance as this might negate the ability to process the claim with the 
carrier).

•  The Company will not be responsible for:

a)  Down drafts or spillage caused by environmental conditions such 

as near-by trees, buildings, roof tops, hills, or mountains.

b)  Inadequate  ventilation  or  negative  air  pressure  caused  by 

mechanical systems such as furnaces, fans, clothes dryers, etc.

•  This warranty is void if:

a)  The fireplace has been operated in atmospheres contaminated by 

chlorine, fluorine, or other damaging chemicals.

b)  The fireplace has been subjected to prolonged periods of dampness 

or condensation

c)  Any damages to the fireplace, combustion chamber, heat exchanger 

or other components due to water, or weather damage, which is the 
result of but not limited to, improper chimney/venting installation.

d)  Any alteration, willful abuse, accident, or misuse of the product 

has occurred.

IF WARRANTY SERVICE IS NEEDED…

1)  Contact your supplier.  Make sure you have your warranty, your 

sales receipt, and the model/serial number of your  Vermont 
Castings, Majestic product.

2)  DO  NOT  ATTEMPT  TO  DO  ANY  SERVICE  WORK 

YOURSELF.

LIMITED LIFETIME WARRANTY 

PRODUCT COVERED BY THIS WARRANTY

All Vermont Castings gas stoves, gas inserts, and gas fireplaces, and all Majestic brand gas fireplaces equipped with 
an Insta-Flame Ceramic Burner, or standard steel tube burner.

Содержание DVHVAC36

Страница 1: ...cannot reach your gas supplier call the re department WARNING IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL INJURY OR LOSS...

Страница 2: ...eral Venting 9 General Venting Information Termination Location 10 General Information Assembling Vent Pipes 11 Twist Lock Pipes 11 How to Use the Vent Graph 12 Sidewall Venting Graph 12 Corner Instal...

Страница 3: ...at the gas valve and pilot light are turned off before you attempt to clean this re place 7 The venting system chimney of this replace should be checked at least once a year and if needed your venting...

Страница 4: ...ci cations Ref DVHVAC36 Ref DVHVAC36 A 36 914 mm N 9 245 mm B 34 870 mm O 6 175 mm C 21 533 mm P 2 58 mm D 33 838 mm Q 2 51 mm E 63 1621 mm R 3 97 mm F 70 1780 mm S 4 102 mm G 16 410 mm T 1 2 13 mm H...

Страница 5: ...Remove the access panel on the front of the air cir culating blower section by removing the 10 24 nuts Remove the jack plug from the air circulating blower motor by gently depressing tab 5 Attach the...

Страница 6: ...depth to suit facing material adjustable to 1 2 5 8 or 3 4 depths Fig 4 5 Screw through slotted holes in drywall strip and then screw into pre drilled holes on replace side Meas ure from face of repl...

Страница 7: ...f any part of it has been under water Immediately call a quali ed service technician to inspect the replace and replace any part of the control which has been under water Gas Inlet Manifold Pressures...

Страница 8: ...test point therefore it is not necessary to pro vide a 1 8 test point up stream of the control When using copper or ex connector use only approved ttings When using black iron pipe always provide a un...

Страница 9: ...BLUE R W1 G Y GND CHASSIS GND 24 VAC RTN 24 VAC HOT TH TP PILE TH PILE THERMOPILE GAS VALVE TP TH TP TH EMERGENCY HEAT SWITCH 14 YELLOW 15 BLUE 13 BLUE 12 YELLOW RED WHITE L1 L2 TP TH TH LIMIT 16 YELL...

Страница 10: ...3 91cm J Clearance to nonmechanical air supply inlet 6 15cm for appliances 10 000 6 15cm for appliances to building or the combustion air inlet to any Btuh 3kW 12 30cm for 10 000 Btuh 3kW 9 other app...

Страница 11: ...suggest putting a lubricant Vaseline or similar on the male end of the twist lock pipe prior to assembly TWL100 Twist Lock Pipe 3 12 99 djt Male End Female End Screw Holes TWL100 Fig 11 Twist lock pip...

Страница 12: ...se applications Refer to Venting Components listed for different installation requirements The maximum horizontal distance between the rear of the appliance and the outside face of the rear wall is 20...

Страница 13: ...rmination 4 collar into the 4 pipe then the 7 collar into the 7 pipe Do not force the venting into position If the pipes do not line up with the termina tion collars disassemble elbows or pipes and re...

Страница 14: ...alled in either the vertical or horizontal run When one 1 90 elbow is installed directly onto another off the back of the replace the maximum horizontal vent length is 36 914 mm Fig 19 For each 45 elb...

Страница 15: ...4 100 Vent Opening 2 99 djt Vent Opening for Combustible Wall 9 240 mm 9 240 mm Fireplace Hearth Framing Detail Vent Opening for Noncombustible Wall 7 190 mm VO584 100 Fig 22 Locate vent opening on wa...

Страница 16: ...uirement STEP 7 Support the horizontal pipes every 36 914 mm with metal pipe straps Make sure the horizontal vent pipe is installed on a level horizontal plane STEP 8 Re check the replace to make sure...

Страница 17: ...pe Straps Every 3 914mm CFM148 Fig 30 Support straps for horizontal runs Up to two 2 45 elbows may be used within the horizontal run For each 45 elbow used on the hori zontal level the maximum horizon...

Страница 18: ...and 7 collars of vertical vent termination and install If there is a room above ceiling level restop spacers must be installed on both the bottom and the top side of the ceiling joists If an attic is...

Страница 19: ...ustable length 7TDVP3566 35 to 64 adjustable length Pipe sections for vertical or horizontal venting Model 7TDVP8 Model 7TDVP12 Model 7TDVP24 Model 7TDVP36 Model 7TDVP48 Firestop Spacer Model 7DVFS At...

Страница 20: ...other airborne particles to cling to the glass surface Also initial paint curing may deposit a slight lm on the glass It is therefore recommended the glass FP1405 DVHVAC remove glass frame 8 03 Clamps...

Страница 21: ...to the ON position This will turn on the replace burner in a low re condition The unit will provide heat to the room in which the replace is installed When power is restored toggle the emergency heat...

Страница 22: ...and logs 2 Place refractory side supports so that the hole ts over the screw head on the rebox oor 3 Place refractory base sides on the oor of the re box 4 Attach adjustable tabs packed with refracto...

Страница 23: ...the oor because some gas is heavier than air and will settle on the oor WHAT TO DO IF YOU SMELL GAS Do not try to light any replace Do not touch any electric switch Do not use any phone in your buildi...

Страница 24: ...An interrupter block not supplied must be used to conduct this test 3 Pilot burning no gas to A Thermostat or wires defective Check wall switch and wires for proper connections main burner Valve knob...

Страница 25: ...tem consist of burner tube gas ori ce pilot assembly thermopile millivolt gas valve Most of these components may require only an occasional checkup and cleaning and some may require adjustment If repa...

Страница 26: ...C parts 7 02 4a b 1e 1f 1d 1c 1b 1a 1195 CFM Corporation reserves the right to make changes in design materials speci cations prices and discontinue colors and products at any time without notice DVHV...

Страница 27: ...t 54273 8b Ori ce Pilot Prop 54272 9 Pilot 3 Way 10001295 10 Pilot Tubing w ttings 53211 11 Manifold Tubing w ttings 57318 12 Thermocouple 53373 13 Thermopile 51827 14 Electrode Ignitor w cable 100012...

Страница 28: ...ang bay window assembly over existing window frame assembly Do not remove existing window frame as sembly 6 Re install upper louvre assembly Remove all plastic from brass trims 7 Bottom brass trim is...

Страница 29: ...29 DVHVAC36 10001195...

Страница 30: ......

Страница 31: ...mageisfoundtobethefaultofthemanufacturer repairs will be authorized at no charge to the customer parts and or labor Any part and or component replaced under the provisions of this warranty is covered...

Страница 32: ...EnerGuide Ratings Steady State D O E Fireplace Ef ciency Fan OFF Fan ON AFUE DVHVAC36RN 76 83 84 77 1 DVHVAC36RP 76 84 85 77 1 410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 800 668 5323 www cfmc...

Отзывы: