MP7500 Router Installation Manual Version 1.0
Ground wire
Live wire
Naught wire
Common power supply jack
Connect the power supply as follows:
•
Step 1: Put the power supply switch to OFF. For AC router, connect
one side of AC power supply cable to the AC power input end of the
back panel of the router and another side to power supply jack
(AC: 220V 50Hz/60Hz) and use the clip to lock the cable; for DC
router, connect the power line to the post according to the
description of panel silk screen on the interface. The cross sectional
area of the lead of the selected power line must be larger or equal
to 2 mm2.
•
Step 2: Put power supply switch to ON.
•
Step 3: Check whether the power supply indicator of the front
panel is on. If not, repeat step 1 and 2.
If the power supply indicator is not on after repeating the above steps,
contact the agent.
Maipu Confidential & Proprietary Information
Page
59
of