UK 

│ 

4. Safety instructions and warnings 

 

14 

Exercise caution when handling 

packaging materials.  

 Observe applicable safety and accident 

prevention requirements.  

 Store packaging material out of the reach 

of children (risk of suffocation). 

 

5. Operation 

Fan and swivel drive are switched on and off 

separately via a switch. 
Special accessories with time-delayed 

switching or humidity function can be used. 
In the event of thermal overload, the fan 

switches off. Wait until the motor has cooled 

down. Cool-down time can take  

up to 10 minutes. 

Unit switches back on 

automatically after cooling down.

 

 

6. Environmental conditions and 

operating limits 

  Permitted ambient and airstream 

tempe 40°C. 

  Information for operation with occasional 

temperatures below -20° on request. 

 

7. Technical data 

Rated voltage 

230 VAC 

Power frequency 

50 Hz 

Power consumption 

ECO 30 E: 37 W 

ECO 40 D: 44 W 

I

max

 

0.25 A 

Sound pressure level  ECO 30 E: 57 dB(A 

ECO 40 D: 65 dB(A) 

Degree of protection 

IP 20 

Weight 

ECO 30 E: 3.1 kg 

ECO 40 D: 4 kg 

 

For more technical data, 

 rating plate. 

For dimensions 

 Fig. C. 

 

8. Transport 

 

NOTICE:

 

Unit damage in case of incorrect 

transport if the fan unit slips out of the 

rotary axes.

  

The 

fan unit

 is inserted in both of the 

bushings/rotary axes and is 

not secured

Therefore, hold the fan by the protective 

cage when removing it from the transport 

box and transport it. 

 

9. Storage 

Store unit exclusively in a dry location  

(-20 to +50 °C). 
 

10. Mounting information 

  Installation only permissible on even, solid 

walls with sufficient load-bearing capacity 

(min. 200 kg/m³). 

  Make sure there is sufficient space 

between the fan unit and the wall and 

ceiling. 

  Can be installed in any position on the 

wall. 

  Swivel axis should preferably be 

horizontal. For other swivel directions, 

feed the power cable through from the 

bottom if possible. 

  Select installation site so that foreign 

bodies will not be accidentally drawn in. 

Observe installation height. 

  Take the risk of draughts into account 

when planning by selecting a suitable 

installation location. 

  To avoid sound bridges with the structure, 

observe distances from other façade 

components and, if necessary, use 

isolating elements. 

  Mounting material that is sufficiently 

dimensioned and suitable for the surface 

is to be supplied by the customer. 

Содержание ECO 30 E

Страница 1: ...Montage und Betriebsanleitung Wandfächer Mounting and Operating instructions Wall fan Instructions de montage et Mode d emploi Ventilateur mural ECO 30 E ECO 40 D www m aico ventilatoren c om DE UK FR ...

Страница 2: ...2 A B C ...

Страница 3: ...3 D E F G H I ...

Страница 4: ... 9 15 Störungsbehebung 9 16 Ersatzteile 10 17 Demontage 10 18 Umweltgerechte Entsorgung 10 1 Lieferumfang ECO Wandfächer 2 Schrauben M3x12 für Klemmenleiste 2 Unterlagscheiben 2 Kunst stoffkappen diese Montage und Betriebs anleitung 2 Qualifikation Fachinstallateur Die Montage ist nur durch Fachkräfte mit Kenntnissen und Erfahrungen in der Lüftungstechnik zulässig Arbeiten an der Elektrik dürfen n...

Страница 5: ...rch brennbare Materialien Flüssigkeiten oder Gase in der Nähe des Ventilators In der Nähe des Ventilators keine brennbaren Materialien Flüssigkeiten oder Gase deponieren die sich bei Hitze oder durch Funkenbildung entzünden und in Brand geraten können Wasserdampfgesättigte oder fett haltige Luft oder am Ventilator anhaftende Feststoffpartikel können den Ventilator verschmutzen und die Leistungsfäh...

Страница 6: ...chern Sorgen Sie dafür dass Sie sicher stehen und sich niemand unterhalb des Gerätes aufhält Gefahr durch Stromschlag bei Be trieb mit nicht komplett montiertem oder beschädigtem Ventilator Vor dem Abnehmen der Abdeckung 3 alle Versorgungsstromkreise abschalten Netzsicherung ausschalten gegen Wieder einschalten sichern und ein Warnschild sichtbar anbringen Ventilator nur komplett montiert betreibe...

Страница 7: ...e von Kindern aufbewahren Erstickungs gefahr 5 Bedienung Ventilator und Schwenkantrieb werden separat per Schalter ein und ausgeschaltet Sonderzubehör mit Zeitverzögerungsschal tung oder Feuchteautomatik einsetzbar Bei thermischer Überlastung schaltet der Ventilator aus Warten Sie bis der Motor abgekühlt ist Die Abkühlzeit kann bis zu 10 Minuten betragen Gerät schaltet nach Abkühlung selbsttätig w...

Страница 8: ...artons ablegen 3 Schwenkwinkel einstellen Werkseinstel lung 90 Zum Ändern der Werksein stellung den Lagerbügel 5 leicht sprei zen rechts und links aus der Lagerbuchse 8 nehmen und Lagerbuchse 9 vom Stift des Exzenterhebels abziehen Exzenterhebel ausbauen Dazu Siche rungsring 12 1 abnehmen Stift 12 herausziehen und an gewünschter Position neu einstecken und sichern für Positionen 55 70 oder 115 Abb...

Страница 9: ...erheitsregeln einhalten 2 Lagerbügel und Ventilatoreinheit mit einem trockenem Tuch reinigen 3 Bei stark verunreinigtem Schutzkorb diesen mit einem angefeuchteten Tuch reinigen 4 Netzsicherung einschalten Warnschild entfernen 15 Störungsbehebung Fehlerfindung und Reparaturen nur durch Elektrofachkräfte Störung Ursache Maßnahme Ventilator schaltet nicht ein Keine Netzspannung Prüfen ob die Netzsich...

Страница 10: ... 0000 Bestelladresse Maico Elektroapparate Fabrik GmbH Steinbeisstraße 20 78056 Villingen Schwenningen Deutschland Tel 49 7720 694 445 Fax 49 7720 694 175 E Mail ersatzteilservice maico de 17 Demontage Die Demontage darf nur von einer Elektrofachkraft vorgenommen werden 1 Netzsicherung ausschalten gegen Wiedereinschalten sichern und ein Warnschild sichtbar anbringen Die 5 Sicherheitsregeln einhalt...

Страница 11: ... disposal 17 1 Scope of delivery ECO wall fan two M3x12 screws for the terminal block two washers two plastic caps these installation and operating instructions 2 Specialist installer qualification Mounting may only be carried out by specia lists who have the necessary knowledge and experience in ventilation engineering Only a trained electrician is permitted to work on the electrics You are deeme...

Страница 12: ...place any flammable materials liquids or gases near the fan which may ignite in the event of heat or sparks and catch fire Steam saturated or greasy air or solid particles which may stick to the fan can soil the fan and reduce the efficiency Never use fan to convey these substances Explosive gases and dusts may ignite and cause serious explosions or fire Never use fan unit in an explosive atmosphe...

Страница 13: ... back on Attach a warning sign in a clearly visible place Comply with the 5 safety regulations Be sure to observe the relevant regulations for electrical installation e g DIN EN 50110 1 in Germany this is particularly VDE 0100 with the corresponding parts A mains isolation device with contact openings of at least 3 mm at each pole is mandatory Only connect unit to a permanently wired electrical in...

Страница 14: ...ting plate For dimensions Fig C 8 Transport NOTICE Unit damage in case of incorrect transport if the fan unit slips out of the rotary axes The fan unit is inserted in both of the bushings rotary axes and is not secured Therefore hold the fan by the protective cage when removing it from the transport box and transport it 9 Storage Store unit exclusively in a dry location 20 to 50 C 10 Mounting info...

Страница 15: ... latching corners unlatch Remove cover Fig E 5 ECO 40 D Pull the capacitor 15 off of the bearing bracket Fig F 6 With electric recessed mounted connection UP Fig D Break out cable feedthrough on the bearing bracket and stick the power cable through this feedthrough in the bearing bracket 7 Mark the drill holes distance 70 mm Fig G insert dowel min Ø 8 mm and screw the bearing bracket to the wall C...

Страница 16: ...age Check whether the mains fuse has failed Switch on if necessary Motor s thermal overload protection has switched the fan off Motor too hot The motor protection switch has switched off the fan Wait until the motor has cooled off The cool down time can take up to 10 mi nutes NOTICE The unit switches back on automati cally after cooling down Fan does not switch on Impeller blocked Check impeller a...

Страница 17: ...u are At the end of its service life dispose of the unit in an environmentally friendly way in compliance with the regulations valid in the country where you are ECO 30 E ECO 40 D Veuillez lire attentivement ces instructions avant le montage et la première utilisation Suivez les instructions Remettez les instructions au propriétaire pour conservation Vue d ensemble de l appareil Fig A et B 1 Hélic...

Страница 18: ...eur mural à la circulation d air dans des locaux commerciaux ateliers de produc tion restaurants ateliers professionnels salles d exposition etc Pendant le fonction nement le ventilateur pivote oscille d avant en arrière et inversement zone de pivotement 55 70 90 ou 115 réglable au montage ECO 30 E avec diamètre de l hélice de 300 mm ECO 40 D avec 400 mm Moteur du ventilateur et entraînement du mé...

Страница 19: ... vapeurs agressifs Dangers dus à l appareil monté au plafond Il est interdit de monter le ventilateur mural au plafond Respecter toutes les consignes de sécurité Danger pour les enfants et les personnes ayant des capacités physiques sensorielles ou psychiques réduites ou sans connais sances suffisantes L installation la mise en service le nettoyage et l entretien du ventilateur ne pourront être ef...

Страница 20: ...r l Allemagne la norme DIN VDE 0100 et les parties correspondantes doivent être respectées Prévoir un dispositif de coupure du secteur avec une ouverture de contact d au moins 3 mm par pôle Brancher exclusivement l appareil sur une installation électrique permanente avec des câbles de type NYM O NYM J 3x 1 5 mm Utiliser exclusivement les appareils à la tension et à la fréquence indiquées sur la pl...

Страница 21: ...aractéristiques techniques supplémentaires Plaque signalétique Pour les dimensions Fig C 8 Transport ATTENTION Endommagement de l appareil suite à erreur pendant le transport si l unité de ventilateur glisse hors des axes de rotation L unité de ventilateur est emboîtée sur les deux douilles axes de rotation mais n est pas bloquée Ne pas sortir le ventilateur mural du carton d emballage en le saisi...

Страница 22: ...e en place à la position choisie et la bloquer pour positions 55 70 ou 115 Fig B Monter l étrier porte palier 5 L écarter avec précaution et l enfoncer dans les deux douilles Ne pas encore enfoncer la goupille du levier excentrique 12 4 Retirer le cache de protection 3 conformément à la Fig D Le cas échéant soulever légèrement de chaque côté avec un tournevis de manière à dégager les 4 coins d arr...

Страница 23: ...ère bien visible Respecter les 5 règles de sécurité 2 Nettoyer l étrier porte palier et l unité de ventilateur à l aide d un chiffon sec 3 Si la cage protectrice est très sale la nettoyer avec un chiffon humide 4 Activer le fusible secteur retirer le panneau d avertissement 15 Élimination des dysfonctionnements Détection d erreurs et réparations uniquement par des électriciens professionnels Dysfo...

Страница 24: ...él 49 7720 694 445 Fax 49 7720 694 175 Courriel ersatzteilservice maico de 17 Démontage Seul un électricien qualifié peut se charger du démontage 1 Désactiver le fusible secteur sécuriser contre toute remise en service intempestive et apposer un panneau d avertissement de manière bien visible Respecter les 5 règles de sécurité 2 Retirer le cache de protection 4 et démonter l appareil 18 Éliminatio...

Отзывы: