9. Spare Parts
Spare parts are usually ordered from your customer service centre
or your local dealer. To ensure quick and correct processing of your
order, the following information is absolutely essential:
1.
Type designation, serial number and voltage of the grinder (on
the rating plate underneath the grinder).
2. An exact description of the part to be replaced or the article
number.
|
H O R E C A
G A S T R O G R I N D E R
Alarm Record
COVER OPEN
LOW VOLTAGE
Cause
Magnet switch
•
open.
Grinder’s cover
•
open.
Switch’s plug
•
not connected
at the proces-
sor board.
Strand of
•
switch defec-
tive.
Magnet switch
•
defective.
Contact mag-
•
net in cover
missing.
Main power
•
board runs at
35% under nor-
mal operation.
Power con-
•
sumption at
outlet too high.
Mains voltage
•
too low.
Correction
After closing the magnet
•
switch press PROG-button.
Grinders are not blocked.
Check the plug/socket
•
of the switch for correct
position.
Bridge the contact in order
•
to rule out defective pro-
cessor board.
Test new magnet switch
•
Glue in a new contact
•
magnet into the cover.
Switch off and on the
•
grinder.
Check mains voltage.
•
Check junction box.