21
BA060801-en
Pos : 73 /T echnisc he Dokumentation/ Alle G erät e/ 01/Übersc hrift en/Übersc hrift en 1. 1. 1/ W/Übersc hrift 1. 1. 1: War mf ahr en @ 18\ mod_1254735635297_75. doc x @ 456961 @ 3 @ 1
4.4.4
Warm-up Drive
Pos : 74 /T echnisc he Dokumentation/ Leis tung/F unktion/ Abg as/ 06 LPS Tr akt or/ 0801 LPS Z W-500/BA/I nhalt : 0608 War mf ahren @ 18\ mod_1254808835404_75.doc x @ 457273 @ @ 1
1 Select suitable transmission/RPM range of the power take-off shaft., switch it on.
2 Select measurement method and confirm with <ENTER>
Measurement with
→
Warm-up drive
<*>
3 Enter performance target value using digit keys.
4 Confirm with <ENTER> key.
Target performance
20 kW
<*>
5 Press accelerator.
Bring Motor up to
RPM
If there is no RPM signal, this message appears:
Warm-up. RPM
too small
The following display appears with applied RPM signal
RPM OK? <*>
n = 500 min
-1
Note: keep motor RPM constant.
Hold Motor RPM
constant
4 When desired RPM is reached, confirm with <ENTER> .
With constant motor RPM, the pre-set target performance
remains constant.
381.9 Nm
20,0 kW
500min
-1
Limits to the LPS
If the max. torque is exceeded, the following display appears:
No measurement values are recorded by the dynamometer,
the RPM continues to be displayed.
-- .-- Nm
--
--
kW xxmin
-1
If the brake is overloaded (warmed up), the following display
appears:
Error Brakes 1
100% driven
Pos : 75 /-----Format-----/MANUELLER UMBRUCH Seit enumbr uc h @ 0\ mod_1134403577687_0. doc x @ 1277 @ @ 1