24
Magtrol Model DSP7000 Dynamometer Controller
Chapter 3 – Installation/Configuration
SETUP
3.2.4
H
ySTereSiS
D
ynaMoMeTer
wiTH
e
DDy
-C
urrenT
or
p
owDer
B
rake
S
eTup
3.2.4.1
Hardware Connection
No Connection
Eddy-Current (WB)
OR Powder Brake (PB)
Dynamometer
AC Mains
Hysteresis Dynamometer (HD)
Excitation
Torque
Speed
TSC 401
Torque-Speed
Conditioner
DES Power Supply
Motor
Under
Test
USB
PC
M-TEST
DSP7002
DYNAMOMETER
CONTROLLER
Figure 3–12 Hysteresis Dynamometer with Eddy-Current or Powder Brake Setup
3.2.4.2
Software Configuration
1. Turn on the DSP7000. Set up TSC1 as described in section
3.2.2 - Hysteresis Dynamometer
Setup
. Press TSC to swtich to TSC2 setup and proceed to the dynamometer configuration
menu.
See Section 3.2.1 – Dynamometer Configuration Menu
.
2. Press PoWER UNITS until Wb or Pb is reached.
3. Press MAx SPEED button and use
and
buttons and Decrease/Increase dial to set
desired scale factor for TSC2.
4. Press SCALE I to add a filter if desired.
5.a. If using an Eddy Current Dynamometer, press ShIFT. The display should appear as follows:
POWER
BRAKE STATUS
SET POINT
SET POINT
P
I
D
TORQUE
SPEED
USER DISPLAY
TSC2
MAX TORQUE
NOMINAL SPEED
X.XXX
XXXX.X
Figure 3–13 TSC2 Eddy-Current Setup Menu
Press the ToRqUE UNITS button and use
and
buttons and Decrease/Increase dial to
set desired max torque. Press the SCALE P button and use
and
buttons and Decrease/
Increase dial to set desired nominal speed. Press ShIFT 4 times to complete the initial setup
and return to the main menu.