14
Magtrol Model DSP7000 Dynamometer Controller
Chapter 2 – Controls
GENERAL
INFORMA
TION
top row
bottom row
POWER
BRAKE STATUS (ON or OFF)
TORQUE
SET POINT (TORQUE)
SPEED
SET POINT (SPEED)
USER DISPLAY
P
I
D
2.3.1
c
ontraSt
S
EttingS
The DSP7000 is shipped with the Contrast Setting at zero (lowest) in order to prolong display life.
If it is necessary to increase the Contrast for improved readability, execute the following steps:
1. Press ShIFT.
2. Press SETUP button.
3. Select SYSTEM
3. Select CoNTR until desired brightness is reached.
4. Press ShIFT 2 times to return to main menu.
Note:
Make sure the lowest possible setting is used to achieve desired
result. Using a setting higher than necessary may cause display
segments to burn-in over a period of time, resulting in uneven
illumination from segment to segment.
2.3.2
S
tatuS
d
iSPlay
M
ESSagES
message
meaning
SHIFT
Shift button was pressed.
MAX SPEED
Maximum motor RPM.
UNITS
Torque unit of measurement.
REMOTE
Remote control via PC enabled.
RAMP DOWN
Decrease motor speed by increasing load on motor.
RAMP UP
Increase motor speed by decreasing load on motor.
SAVING
Saves current configuration of unit to non-volatlie memory.
RAMP DU
Decrease motor speed and then increase motor speed
POWER UNITS
UNITS
Torque units