Note:

  to  avoid  problems  with  interference,  the  Magstim  Bistim²  system  should  not  be  used  in  the 

vicinity  of  any  equipment  not  in  compliance  with the  EMC  Standard  EN  60601-1-2, including  mobile 
phones. 

Note:

 Please ensure you are familiar with all sections of this operating manual prior to following these 

operating instructions. 

Note:

  Please  consult  any  labelling  and  information  accompanying  stimulating  coils  and  other 

accessories for safety and use information regarding these devices. 

Note: 

UI  functions  described  in  this  section  are  to  be  performed  on  the  master  unit  UI  (Bistim²  UI). 

Control functions/buttons are not activated on the slave unit UI (200² UI) therefore cannot be used to 
control system. The only function/button that may be used is the system stop button. 

 

4.1 

Preparation 

1.  At  the  start  of  each  session  the  operator  must  check  the  Magstim  Bistim²  system  and  any 

accessories used for any signs of external damage and to identify any cleaning required

*

. If any 

cracks are visible in the housing, or there is damage to any of the cables, the items must not be 
used  and  should  be  returned  to  The  Magstim  Company  Limited  for  servicing  and  repair.  If 
cleaning is required, please follow the instructions in Section 5 of this Operating Manual. 

Note:

 The contacts in the coil connector, Bistim² connecting module and the stimulator coil output 

socket should be checked regularly for any signs of tarnishing or burning*. See Section 5.2 for an 
example of contact burning. 

 

4.2 

Set-up 

Note:

  The  Magstim  BiStim²  should  be  assembled  following  the  instructions  provided  within  this 

section to ensure continued compliance of IEC 60601-1:2005. 

 

Note: 

ensure not to position the Magstim BiStim², so it is difficult to disconnect the power lead. 

1.  Ensure that the master and slave units of the Magstim Bistim² are switched off on the rear

*

2.  Place  the  master  unit  on  top  of  the  slave  unit  ensuring  the  feet  of  the  master  unit  fit  into  the 

recesses on the slave unit

*

.  

3.  Remove the two blanking plugs from the threaded inserts on the left-hand side of the master unit. 

4.  Insert  the  two  M6x60  hexagon  bolt  into  the  mounting  holes  on  the  Bistim²  Connecting  Module. 

Place the Bistim² Connecting Module against the side of the master unit so that the bolts locate in 
the threaded inserts. Ensure that the coil output socket is facing the front

*

. (See Figure 4.1) 

5.  Using the supplied hexagon key tighten the bolts so as to secure the Bistim² Connecting Module 

to the side of the master unit*. Do not over tighten the bolts as this may damage the cases of the 
units. 

6.  Fit  the  two  supplied  blanking  inserts  to  the  mounting  holes  in  the  Bistim²  Connecting  Module. 

These blanking plugs are a push fit but care is needed with the positioning of the inserts to ensure 
that the tops are flush with the case surface. 

Содержание BiStim2

Страница 1: ...January 2014 Magstim BiStim Operating Manual MOP02 EN Revision 02...

Страница 2: ...4 4 Operation 14 4 5 Independent BiStim Triggering IBT 15 Section 5 Maintenance 16 5 1 User Maintenance and Calibration 16 5 2 Technical Maintenance 16 5 3 Voltage Selection and Fuse Rating 17 5 4 Cle...

Страница 3: ...al service Claims for damages during shipment must be filed promptly with the transportation company All correspondence concerning the equipment must specify the model name and or number as well as th...

Страница 4: ...gstim Bistim is a non sterile reusable medical device intended for multi patient use The Magstim Bistim is not intended to come into contact with the patient as this achieved through use of a stimulat...

Страница 5: ...ent environment Note When the Bistim Connecting Module is not connected the Magstim 200 Units will operate as if they were a standalone device Please consult the Magstim 200 Operating Manual before us...

Страница 6: ...d to the Magstim Bistim This connection must be configured in compliance with IEC 60601 1 1 2000 or Clause 16 of IEC 60601 1 2005 Second edition IEC 60601 1 1 with the following interface voltage limi...

Страница 7: ...ng manual Stacking Limit Magstim 200 units may be stacked on top of each other but must not exceed the stacking limit specified in Section 6 of this operating manual If this limit is exceeded the stac...

Страница 8: ...trol system The only function button that may be used is the system stop button Figure 3 1 Detailed front panel The upper unit is considered the master unit The lower unit is considered the slave unit...

Страница 9: ...g connected correctly to the Magstim Bistim 3 1 6 Coil Temperature Indicators 6 These LED s represent the surface temperature of the coil The LED s illuminate sequentially as the coil temperature rise...

Страница 10: ...eases the level To toggle between the master power slave power and inter pulse spacing press the output control Each complete 360 rotation changes the master slave power output level by approximately...

Страница 11: ...MOP02 EN 02 Note It is normal for the pin indicated on the label to protrude from the coil socket on the master and slave stimulator units This is an intentional design feature Figure 3 2 Coil output...

Страница 12: ...xternal trigger input This is only functional on the master unit Please see Appendix B for more information 3 2 3 Foot Switch Socket 3 This socket is used to connect the pneumatic foot switch to the M...

Страница 13: ...unit prior to the unit being switched on 3 3 Accessories A range of stimulating coils are available for use with the Magstim range of products For more details please contact the Sales department Cont...

Страница 14: ...ating Manual Note The contacts in the coil connector Bistim connecting module and the stimulator coil output socket should be checked regularly for any signs of tarnishing or burning See Section 5 2 f...

Страница 15: ...key tighten the bolts so as to secure the coil holder to the right hand side of the master unit Do not over tighten the bolts as this may damage the cases of the units Figure 4 2 Attaching the coil ho...

Страница 16: ...l holder on the right hand side of the stimulator as instructed in Figure 4 3 Figure 4 4 Attaching the coil to the coil holder 5 Connect the stimulating coil to be used to the coil output socket on th...

Страница 17: ...ster unit UI to adjust the power level or the inter pulse spacing to the desired setting Rotating the control clockwise increases the power level rotating anti clockwise decreases the power level 4 De...

Страница 18: ...nnect the Magstim Bistim Note Ensure that the system is disarmed prior to disconnecting the stimulating coil and BiStim connecting module 4 5 Independent BiStim Triggering IBT When the system is set i...

Страница 19: ...ossible for localised heating to manifest itself in the connector which causes damage to the contacts Continued use in this condition will eventually cause the contacts to deteriorate and loose electr...

Страница 20: ...voltage selector to the desired setting and replace the cover A legend will indicate the voltage selected when the fuse cover is replaced Note Only replace fuses with those of the correct rating and...

Страница 21: ...erviceable life it should not be disposed of in general waste The Magstim Company Limited should be contacted see Section 7 2 for contact details for advice on its disposal in compliance with the appr...

Страница 22: ...ot comply with EMC Safety Standard EN 60601 1 2 including mobile phones Any interface cable which connects the Magstim Bistim unit to an external piece of equipment must be no more than 1 5m in length...

Страница 23: ...ife expectancy 2 x 10 6 discharges at 70 power level 8 x 10 5 discharges at 80 power level 4 x 10 5 discharges at 90 power level 2 x 10 5 discharges at 100 power level Isolated Interface Logic High Vo...

Страница 24: ...ering 6 5 Packing Instructions If for any reason it is necessary to return your Magstim Bistim care should be taken to ensure that the equipment is adequately packed to prevent transit damage Ideally...

Страница 25: ...imited Spring Gardens Whitland Carmarthenshire SA34 0HR Telephone 44 0 1994 240798 Fax 44 0 1994 240061 E mail info magstim com Website www magstim com 7 2 Servicing Enquiries Telephone 44 0 1994 2429...

Страница 26: ...gory C04 Invalid Power Identification C05 Temperature sensor circuit failure C06 Bad Serial command or received data checksum C07 Internal Software Error C08 Invalid Coil Temperature ID C09 Invalid te...

Страница 27: ...ck max difference E75 HVCAP over temperature E76 HV Transformer over temperature E77 Charge threshold failure E78 VREF check failure E79 HVCAP voltage comparison failure E80 Charging fault E81 HV over...

Страница 28: ...Bistim will only be triggered when the logic level being applied on the Tin or Tin pin is changed On the Tin pin triggering will occur when the logic level is changed from low to high On the Tin pin...

Страница 29: ...romagnetic environment in which radiated RF disturbances are controlled The customer or the user of the Magstim Bistim can help prevent electromagnetic interference by maintaining a minimum distance b...

Страница 30: ...ital environment Voltage dips short interruptions and voltage variations on power supply input lines IEC 61000 4 11 5 UT 95 dip in UT for 0 5 cycle 40 UT 60 dip in UT for 5 cycles 70 UT 30 dip in UT f...

Страница 31: ...tance in metres m Field Strengths from fixed RF transmitters as determined by an electromagnetic site survey a should be less than the compliance level in each frequency range b Interference may occur...

Отзывы: