35
AUTOMATIC FEATURES
A.
THERMOSTAT OPTION:
When using a thermostat, set the stove to one of the medium or higher settings. The stove will
burn at the rate selected on demand by the thermostat (medium to high).
When the room temperature drops below the thermostat setting, the thermostat switch will
close, allowing the stove to operate at the medium or higher settings. When the room
temperature matches the thermostat setting, the thermostat switch will open, allowing the stove
to operate at the low setting.
B.
THERMOSTAT EQUIPMENT REQUIRED
(optional): A low voltage millivolt
thermostat that will automatically switch between settings previously selected.
Type CL2 thermostat wire-20 AWG, 2 conductors.
C.
STOVE PRESSURE SENSOR:
A blocked flue, a down draft, open door, open hopper lid, negative or positive pressure in the
home, drafty location of the appliance, not hooking up the outside air, improper venting or
failure to clean the 3” exhaust in the stove will cause the pressure switch to shut off the fuel
feed. To resume operation, it is necessary to locate the cause and correct it. Restart the stove
following the instructions in this manual.
D.
HIGH TEMP THERMODISK:
If the stove overheats, it will shut itself down safely. The stove may not be restarted until it
has cooled and the reset button is depressed. (See Thermodisk location section) If the auger
does not turn after cleaning the back of the unit, you might have tripped this disk. Check it by
pressing in on the center button until it clicks into place.
E.
SELF-IGNITER:
Automatically ignites the pellets within 3-5 minutes, without the use of fire starter. The igniter
will continue to run for approximately 10 minutes until a fire is established. If the fuel is wet,
poor quality or the hopper not primed, it might take 2-3 cycles for the unit to properly light.
Using a little fire starter will help with this.
F.
PROOF OF FIRE THERMODISK:
If the temperature required by the PROOF OF FIRE thermodisk is not high enough within the
10 (15 minutes on the AC models) minute cycle, the auger will stop feeding pellets. The proof
of fire and cool down sensor are combined into one 110 degree auto reset thermo disk.
G.
COOL DOWN SENSOR:
After the power switch has been moved to the “OFF” position, the blowers will continue to run
for approximately 45 minutes. The cool down sensor will allow the stove to cool down and
then automatically shut itself off. If the hopper runs out of pellets and the stove cools off, the
auger will stop feeding. However, the blowers will continue to run until the power switch has
been moved to the “OFF” position.
Содержание T40AC
Страница 20: ...20 MAGNUM T40I INSERT INSTALLATION...
Страница 22: ...22 T40I INSERT INSTALLATION cont...
Страница 24: ...24...
Страница 25: ...25...
Страница 26: ...26 Thermostat wire connection Low voltage thermostat Molex Plug 24 volt thermostat hookup...
Страница 40: ...40 AC MODEL WIRING DIAGRAM WARNING DISCONNECT POWER BEFORE SERVICING THIS UNIT DHC 3000 AC board...
Страница 41: ...41 DC MODEL DDC 3000 WIRING DIAGRAM WARNING DISCONNECT POWER BEFORE SERVICING THIS UNIT...