A proper draft setting is crucial to the successful burning of solid fuels.  Draft refers to the amount of air 
flowing through the burn chamber of your stove.  Too much or too little draft will cause your stove to 
burn improperly and may result in the fire burning out.  Please follow these guidelines carefully as you 
operate your stove to achieve maximum efficiency and enjoyment. 
 

9

 

The amount of draft required for your stove to burn properly will depend upon your installation and 
the fuel you use. You can set your draft by looking at the flame and following these guidelines.  The 
manual draft knob is the rod and knob on the left side of the stove.  Pulling the knob out increases the 
draft and pushing the knob in decreases the draft.  A little movement of the knob goes a long way to 
changing the flame.  It may take several trial and error adjustments on the draft to achieve the correct 
setting. 

 

9

 

The flame should be an “active” flame.  A flame that moves around lazily and emits visible smoke 
needs more draft.  To give the fire more draft, pull the damper out 1/8” and check the flame again.  If 
the status of the flame has not changed, move the damper another 1/8” until you get a clean “dancing” 
flame. 

If moving the damper does not change the fire, you might have negative pressure in the 

home.

 

 

9

 

The base of the flame should be blue in color and the top of the flame should be white will some 
yellow.  

 

9

 

If the flame does not have enough draft, fuel will build up in the firepot and eventually smother the 
flame.  If this happens, or if you notice the firepot is filling up with partially burned fuel, open the 
damper 1/8” at a time until the fire is clean and dancing. If this continues and moving the draft knob 
does not change anything, you probably have a negative air problem and need to have a service tech 
take a look at your installation.  

Do not operate the unit if smoke is being pulled into the home. 

 

9

 

If the flame has too much draft, the flame will look like a torch in that it will be moving rapidly and 
blowing fuel out of the firepot.  If you find that you have this condition, move the damper inward 1/8” 
at a time until the condition of the flame changes. 

 

9

 

If the fuel crusts over, you will need to check into the fuel quality.  This will also be a problem if you 
do not have outside air hooked up or if your home is starving for fresh air. 

 
 
 
 
 
 
 
 
 
 
 
 
 

SETTING THE DRAFT 

Содержание T40AC

Страница 1: ...ws and fittings must be airtight proper venting practices must be followed Consult with a venting professional 9 Ashes must be disposed of in a metal container with a tight fitting lid 9 All minimum c...

Страница 2: ...and Replacement 36 Circuit Board Functions 37 38 Setting the Draft 39 Wiring Diagram AC DC 40 41 Draft Slide Gate Adjustment 42 Igniter Replacement 43 Trouble Shoot Guide 44 45 46 47 Warranty 48 Servi...

Страница 3: ...ergy Systems Inc manufacturer of the Magnum Wood Pellet Appliances reserves the right to alter its products their specifications and or price without notice Safety tested and EPA exemption tested by W...

Страница 4: ...t could be that there is a serious lacking of good quality air in the home caused by negative pressure If you have done any remodeling or if this is a newer home it is a very real possibility that thi...

Страница 5: ...approved for this appliance it will void the warranty and no service warranty will be allowed The Magnum models will burn high ash content fuels but will require additional maintenance cleaning 9 A wo...

Страница 6: ...to using and selecting proper fuels for your stove WOOD PELLETS 9 Be consistent in your wood pellet fuel supplier Wood Pellets will vary in content and burn characteristics from supplier to supplier...

Страница 7: ...Make sure that the shroud is with the unit when you get it The following diagram will show how to install the legs on the Leg Unit The legs are wrapped up and packaged in the hopper Unpackage the leg...

Страница 8: ...ombustible material or equivalent extending beneath heater and to the front side rear as indicated CHIMNEY AND CONNECTOR 3 LISTED PELLET VENT ONLY NOTE REGARDLESS OF STOVE CLEARANCE VENT PIPE MUST ALW...

Страница 9: ...gases are not hot enough to ignite grass plants or shrubs located in the vicinity of the termination The grade surface must not be a lawn Distance from bottom of termination and public walkway is 7ft...

Страница 10: ...nt pipe length should not exceed 30 feet Component Equivalent Length Equivalent Pipe Length Horizontal Straight Pipe Actual Length in ft x 1 0 Horizontal Pipe 1 x 2 1 3 ft Vertical Straight Pipe Actua...

Страница 11: ...equate fresh air to the home so that the Magnum appliance does not become the fresh air source 4 Only non combustible pipe 3 inches in diameter is approved to use for outside air connections straight...

Страница 12: ...ocal building codes fire codes and the safety listing tag on the inside hopper lid An outside air source must be connected to the stove and can be brought in through the sidewall or vented crawl space...

Страница 13: ...FOLLOWING REQUIREMENTS ARE MANDATORY FOR INSTALLATION IN A MOBILE HOME 1 Stove must be permanently bolted to the floor 2 Stove must have permanent outside air source 3 Stove must be permanently elect...

Страница 14: ...er the pipe manufacturer s instructions Connect the pipe and lock the joints as directed by the pipe manufacturer and secure the vent pipe to the flue collar on the back of the stove Add a small bead...

Страница 15: ...Note The pipe lengths shown are for reference only Your actual pipe length requirements may differ SINGLE WALL PIPE SHALL NOT BE USED FOR ANY INSTALLATION HORIZONTAL INSTALLATION SHALL BE A MAXIMUM O...

Страница 16: ...es and presence of all necessary parts including a chimney cap prior to making the connection 3 This stove may be connected to an existing ceiling mounted factory built chimney with a diameter of 4 6...

Страница 17: ...s ash buildup premature failure of exhaust system staining of the house siding and serious creosote buildup This installation should not be used in a cold climate area Storm Collar Note This type of i...

Страница 18: ...wo terminals on the back of the control panel When the room temperature drops below the thermostat setting the thermostat switch will close allowing the stove to operate at the medium or higher settin...

Страница 19: ...o the two terminals on the back of the control panel When the room temperature drops below the thermostat setting the thermostat switch will close allowing the stove to operate at the medium or higher...

Страница 20: ...20 MAGNUM T40I INSERT INSTALLATION...

Страница 21: ...21 T40I INSERT INSTALLATION cont Siding Use only rigid Pellet Vent pipe Framing Chimney cap Storm Collar Seal Plate 3 75mm Minimum Clearance Around vent 6 150mm min 16 375mm minimum 6 150mm minimum...

Страница 22: ...22 T40I INSERT INSTALLATION cont...

Страница 23: ...ir to the top of the chimney It is best to route the fresh air intake either out the back of the fireplace cavity or down and out to an outside air source Running the fresh air up and out the top of t...

Страница 24: ...24...

Страница 25: ...25...

Страница 26: ...26 Thermostat wire connection Low voltage thermostat Molex Plug 24 volt thermostat hookup...

Страница 27: ...lack negative lead to the negative battery terminal 10 Reconnect the 110 volt AC power The stove is now ready for 12 volt back up and will switch automatically to 12 volt operation when AC power is lo...

Страница 28: ...will stop feeding and You will need to start the cycle over again Pushing and holding the Auger switch allows you to prime the auger and add fuel to the firepot automatically This can be done app 1 mi...

Страница 29: ...ou to prime the auger and add fuel to the firepot automatically Press and hold the button until you have the right fuel load Do not continue to hold the auger button under normal operation as it could...

Страница 30: ...od in or out An air damper closed too much will produce a lazy and slow flame Adjusted properly the flames should be bright and lively Altitude and fuel types greatly affect the amount of air required...

Страница 31: ...ed WARNING MANY HOME VACUUM CLEANERS ALLOW ASH TO ESCAPE INTO THE ROOM AIR HOWEVER VACUUMING IS RECOMMENDED OCCASIONALLY TO AID IN SEASONAL CLEANING AND KEEP THE UNIT FREE OF EXCESS ASH DISCARD THE VA...

Страница 32: ...odically they should be inspected and vacuumed clean The combustion blower is accessed by removing the stove s right side panel and then removing the inspection caps or the exhaust manifold cover See...

Страница 33: ...l accumulate dust cat hair etc on the blades during the heating season This must be vacuumed clean as often as necessary If you have pets they will need to be cleaned Auto reset 110 deg Normally open...

Страница 34: ...remove these products periodically to eliminate the possibility they will be ignited in the chimney and produce damage to the chimney or even possibly destroy the home Clean the chimney as often as n...

Страница 35: ...ill shut itself down safely The stove may not be restarted until it has cooled and the reset button is depressed See Thermodisk location section If the auger does not turn after cleaning the back of t...

Страница 36: ...glass will break when tightening the screws if the glass is on the gasket Hold the glass toward the top of the door glass channel when tightening CLEANING THE GLASS When the fire is first started it w...

Страница 37: ...hest setting Optimum efficiency is achieved by using lower settings 2 or 3 It is also recommended that the unit not be run for extended periods of time on the number 1 setting The draft blower and ven...

Страница 38: ...e ability to use 3 separate programming features This programming must be done by a qualified factory trained technician Contact your local dealer to set up an appointment to have this done The unit a...

Страница 39: ...flame again If the status of the flame has not changed move the damper another 1 8 until you get a clean dancing flame If moving the damper does not change the fire you might have negative pressure in...

Страница 40: ...40 AC MODEL WIRING DIAGRAM WARNING DISCONNECT POWER BEFORE SERVICING THIS UNIT DHC 3000 AC board...

Страница 41: ...41 DC MODEL DDC 3000 WIRING DIAGRAM WARNING DISCONNECT POWER BEFORE SERVICING THIS UNIT...

Страница 42: ...position the plate will be against the mounting plate as shown If the unit needs a draft correction adjustment the bolts are loosened and the slide gate is rotated a few degrees at a time until the p...

Страница 43: ...gniter is flush with the outside of the igniter housing tube Do not tighten the set screw very tight onto the igniter shaft Barely tightening it is enough If you over tighten the set screw it may ruin...

Страница 44: ...ess plates 9 Change to a better grade of fuel if necessary 9 Check that damper control knob is adjusted properly Pull out to increase fire burn 9 Push ash cleanout slides in 9 Check gasket seal around...

Страница 45: ...t board pressure switch or relay 9 Check contents of the hopper Add fuel if necessary 9 Check all operation fuses re set manual high limit thermodisk 9 Clean out auger system 9 Have your Magnum resell...

Страница 46: ...house 9 Clean the glass when the unit is not running 9 Seal any leaks in the exhaust system with RTV high temperature silicone sealer 9 Use approved ash Vacumm 9 Correct negative pressure situation 9...

Страница 47: ...o much ash Dirty fuel Wet fuel Lack of clean combustion air Dirty or plugged stove or venting Poor exhaust vent configuration Negative pressure present in the home Combustion motor going out Use combu...

Страница 48: ...Gold Door Finish only re finish gold door 208 RP2070 T40 Gold Door complete door assembly 372 RP2072 T40 Black Door complete door assembly 163 RP2075 Essex Gold Door Finish only re finish gold door 20...

Страница 49: ...and liability under this warranty is limited to the repair or replacement of the covered defective part The purchaser shall assume all costs related to shipping the replacement parts or return of the...

Страница 50: ...50 SERVICE RECORD DATE SERVICE OR CLEANING PERFORMED This record must be sent in when any warranty claims are made...

Отзывы: