4
You can attach the spark igniter to the bracket hand tightening the plastic nut to make sure that it does
not get over tightened or stripped. Make sure that the wire for the spark igniter is in place on the back
of the spark igniter.
Attach the gas line to the inlet of the gas valve. ( this should be on the left side ) It is highly
recommended that you install a drip in the line right before the valve to assure that water and junk does
not get into the valve. Make sure that the line is cleaned and blown out to assure that there are no
filings or pipe dope that will get into the valve. Make sure that you install a shutoff within the required
distance of the unit. ( see the instructions included with the SP-40-ZC log set )
IMPORTANT: You must pressure test the line before hooking onto the valve. Excess pressure
will destroy the valve. Make sure that the inlet pressure is reduced to the correct pressure before
hooking up the gas line to the valve. ( see the instructions included with the SP-40-ZC log set. )
Attach the pilot assembly to the gas pan on the right side using the screws provided. Make sure that
the pilot and igniter assembly is in the correct position. See Fig. 5
Route the spark igniter wire to the spark igniter whichever way is the best. Either you can hook it up
first down below and then hook it up the pilot assembly or reverse.
Route the pilot gas line and the main burner gas line to the right side of the valve, clean and debur ends