MAGNUM DIGITAL CONTROLLER (MDC) INFORMATION DISPLAYS, FUNCTIONS AND
RESET
The Magnum Digital Controller (MDC) constantly monitors vital generator and engine functions for a number of
operation, alarm and fault conditions. When a fault condition occurs, the engine will shut down automatically and
the Liquid Crystal Display (LCD) window will show the fault that has caused the shut down. To resume operation,
the fault condition must be resolved. To reset the controller and resume operation, press the “FAULT RESET”
button.
MAGNUM DIGITAL CONTROLLER (MDC) – GENERATOR OPERATIONAL STATUS
The Magnum Digital Controller (MDC) displays the operational status of the generator using the following codes:
MAGNUM DIGITAL CONTROLLER (MDC) - ALARM MANAGEMENT
The Magnum Digital Controller (MDC) is capable of displaying the following alarms:
No. Engine
State
Machine
Description
1
AfterCool
Engine aftercooling, Cooling Pump output is closed.
2
Cooling
The generator is cooling before stop.
3
Cranking
Engine is cranking.
4
EmergMan
Emergency Manual gen-set operation.
5
Init
Autotest during controller power on.
6
Loaded
The generator is running at nominal speed and GCB OPEN/CLOSE is
closed.
7
Not Ready
The generator is not ready to start.
8
Pause
Pause between start attempts.
9
Prestart
Prestart sequence in process, Prestart output is closed.
10
Ready
The generator is ready to run.
11
Running
The generator is running at nominal speed.
12
Shutdown
Shut-down alarm is activated.
13
Starting
Starting speed is reached and the
Idle timer
is running.
14
Stop
Stop
No. Electrical
State
Machine
Description
1
StabilTO
Stabilization Timeout
No. Type
Description
1
Sensor fail (FLS)
Sensor fail is detected when measured value is 6% out of the selected
characteristic. Sensor fail indicated by ##### symbol instead measured
value.
2
Warning (WRN)
When warning comes up, see list of possible alarms.
3
Shut down (SD)
When the shut-down alarm comes up the Magnum Digital Controller opens
outputs GCB CLOSE/OPEN, FUEL, SOLENOID, STARTER AND
PRESTART to stop the engine immediately.
23
Содержание MMG 230
Страница 1: ...230 www m p llc com DIESEL GENERATORS MMG 125 MMG 155 MMG 180 MMG 230 OPERATING MANUAL...
Страница 14: ...SERVICE LOCATIONS 14...
Страница 45: ...TRAILER LIGHTS WIRING DIAGRAM 45...
Страница 46: ...46 NOTES...
Страница 47: ...47 SERVICE LOG OIL GRADE AND TYPE BRAND COOLANT MIXTURE BRAND...
Страница 48: ...REV J PART NO 22070 10 20 08...