5
OPERATING SAFETY
Before using the generator be sure you read and understand all instructions! Equipment operated
improperly or by untrained personnel can be dangerous! Read the operating instructions and familiarize
yourself with the location and proper use of all instruments and controls. Inexperienced operators should
receive instruction from someone familiar with the equipment before being allowed to operate or set up the
generator.
The area immediately surrounding the generator should be clean, neat, and free of debris.
Position and operate generator tower on a firm, level surface.
NEVER start a unit in need of repair.
NEVER modify the generator or use it in a manner other than what it was designed for.
ALWAYS keep the generator doors closed when the engine is running. Do not start the generator if any
panels or guards are loose or missing.
ALWAYS connect the generator to a good earthen ground.
Move the generator main circuit breaker to the “OFF” position when servicing or troubleshooting the unit.
The output voltage of the generator can cause a fatal electric shock. Avoid contact with any alternating
current wiring when the engine is running. Make sure any extension cords or equipment connected to
the convenience outlets are in good working condition.
NEVER remove control box cover when the engine is running. Exposed live electrical terminals can
cause a fatal electrical shock.
Check your electrical requirements before installing or starting the generator.
Use a ground fault circuit interrupter (GFCI) in damp or highly conductive areas and construction sites
to prevent electrical shock.
ENGINE SAFETY
Internal combustion engines present special hazards during operation and fueling! Failure to follow the
safety guidelines described below could result in severe injury or death. Also read and follow all safety
warnings described in the Engine Operator's Manual. A copy of this manual was supplied with unit when
it was shipped from the factory.
DO NOT run engine indoors or in an area with poor ventilation unless exhaust hoses are used.
DO NOT fill fuel tank near an open flame, while smoking, or while engine is running.
DO NOT fill tank in an enclosed area with poor ventilation.
DO NOT touch or lean against hot exhaust pipes or engine cylinder.
DO NOT operate with the fuel tank cap loose or missing.
DO NOT remove engine coolant cap while engine is hot.
DO NOT clean air filter with gasoline or other types of low flash point solvents.
Keep area around exhaust pipes and air ducts free of debris to reduce the chance of an accidental fire.
Shut the engine down if any of the following conditions exist during operation:
A. Noticeable change in engine speed.
B. Loss of electrical output.
C. Equipment connected to the generator overheats.
D. Sparking occurs.
E. Engine misfires or there is excessive engine/generator vibration.
Содержание MLG 25
Страница 1: ...25 www m p llc com DIESEL GENERATOR MLG 25 OPERATION PARTS MANUAL...
Страница 28: ...28 ENCLOSURE ASSEMBLY 4 3 5 6 1 9 8 11 14 7 16 15 10 13 12 24 22 21 19 20 18 17 9 10 5 6 3 25 26 23 21 2 27...
Страница 30: ...30 AUXILIARY OUTLET PANEL ASSEMBLY 1 2 8 9 5 4 3 6 7 10 11 13 12 14 15 17 16 18...
Страница 34: ...ENGINE COOLING ASSEMBLY 34 1 2 3 7 3 12 6 22 4 5 2 1 13 14 15 16 17 8 19 20 9 6 11 18 10 21 6...
Страница 48: ...48 ALT EXIT ALT EXIT FUEL FUEL PUMP PUMP MLG 25 DC WIRING DC WIRING SCHEMATIC FOR UNITS BUILT PRIOR TO MAY 2006...