17
Default programming
S-r
:
Room temperature
A floor sensor is not present, the unit will be controlled via internal sensor and display as room temperature.
r-F: Dual temperature control
The thermostat will control based on actual room temperature detected by internal sensor and compare the
floor temperature limitation set by parameter 8.If floor temperature higher than limitation, it wil stop working
and alarm E4.If floor sensor is not connected under r-F mode, it will alarm E2.
S-F: Floor temperature control
Thermostat will control via external sensor and display as room temperature.
NTC function selection
z
z
z
z
Default programming (Adjustable in the App)
Sensor selection:
S-r: Control via room sensor
The thermostat is controlled by an internal sensor and displayed as room temperature.
r-F: Control via room sensor with floor sensor limit
The thermostat controls based on the actual room temperature detected by the internal sensor and
compares it to the floor temperature limit set by parameter 8. If the floor temperature exceeds the limit, the
system stops working and alarms E4. If the floor sensor is not connected in r-F mode, it gives alarm E2.
S-F: Control via floor sensor
The thermostat controls via an external sensor and displays the room temperature.
Cooling mode
Heating mode
Morning
Morning
Leaving home
Back home
Leaving home
Back home
Night
Leaving home
Back home
Leaving home
Back home
Night