Introduction
Figure 1-2, Electrical Connection Points
9
10
8
7
12
11
Positive (+)
DC Terminal
Negative (–)
DC Terminal
Mounting
Flange
DC
Equipment
Ground
Terminal
AC Entry/Exit
Connections
Intake Air Vents
(and on right side)
7
DC Equipment Ground Terminal
– ties the exposed chassis of the inverter to the DC
grounding system. Accepts CU/AL conductors from #14 to #2 AWG (2.1 to 33.6 mm
2
).
8
AC Entry/Exit Connections
– two 3/4” knockouts with cable-clamp
strain relief
s to
accommodate and hold the AC input and output
fi
eld
wiring.
9
Intake Air Vents
–
ventilation openings that pull in air to keep the inverter cool for peak
performance.
10
Positive DC Terminal
– a 360 degree connection point for the positive (+) cable from
the battery bank. Includes a 5/16-18 stainless Kep or Flange nut on a 5/16-18 bolt
(5/8” usable length) that holds the battery cable to the positive DC terminal.
11
Negative DC Terminal
– a 360 degree connection point for the negative (–) cable
from the battery bank. Includes a 5/16-18 stainless Kep or Flange nut on a 5/16-18 bolt
(5/8” usable length) that holds the battery cable to the negative DC terminal.
12
Mounting Flange
– secures the inverter to a shelf or wall.