4. Troubleshooting and Specifications
Fault Conditions
Low Battery –
The unit has shut down because the battery voltage is b e l o w t h e s e t
p o i n t i n L B C O . I t w i l l a u t o m a t i c a l l y r e s t a r t when battery
voltage rises above 12.5 VDC.
High Battery –
The unit has shut down because the battery voltage has exceeded 15.5
VDC. It will automatically restart when the battery voltage drops below
15.5 VDC.
Overtemp –
The unit has shut down because the temperature at the transformer or FET
board has exceed the safe temperature o p e r a t i n g ra n g e . I t w i l l
a u t o m a t i c a l l y r e s t a r t a f t e r u n i t c o o l s down.
AC Overload –
The unit has shut down because the AC load connected to the inverter’s
output exceeded its maximum output rating.
N O T E : W h e n t h i s o c c u r s , r e d u c e t h e l o a d a n d M A N U A L L Y
restart the unit .
Specifications
Electrical Requirements 12 VDC
Controls
C h a r g e r ( O N / O F F ) ,
Inverter (ON/OFF)
LED Indicators
Power, Fault, Charger, Inverter
S o f t K e y s
S h o r e , A G S , M e t e r , S e t u p , T e c h
S e l e c t o r S w i t c h
Rotary (press to accept)
Display
L C D ( 2 l i n e )
Cable type
4 wire twisted pair
W e i g h t
0.5 lb (0.22 kg)
D i m e n s i o n s
3.75" H x 5.75" W x 1.125" D
(9.5 cm H x 16.6 cm W x 2.9 cm D)
C u t o u t D i m e n s i o n s
2.75" H x 4.75" W (7 cm
H x 12 cm W)
Specifications at 25 °C - subject to change without notice.
Ó
2003 - Magnum Energy, Inc.
11
Содержание ME Series
Страница 1: ...ME Series Inverter Chargers Operator s Manual ...
Страница 7: ...1 INTRODUCTION Figure 1 ME Series Inverter Charger Ó 2003 Magnum Energy Inc 2 ...
Страница 15: ...10 Ó 2003 Magnum Energy Inc ...
Страница 20: ...combined battery capacity 400 AHr 12 VDC 14 Ó 2003 Magnum Energy Inc ...
Страница 24: ...Ó 2003 Magnum Energy Inc 17 ...
Страница 33: ...Ó 2003 Magnum Energy Inc ...
Страница 45: ...Remote Control for ME Series Inverter Chargers Operator s Manual ...
Страница 47: ......
Страница 50: ...3 Operation Figure 2 Remote Control Font Panel Ó 2003 Magnum Energy Inc 4 ...
Страница 61: ...1 0 TROUBLESHOOTING 1 1 ME SERIES 1 2 RD SERIES 1 3 REMOTE ...
Страница 62: ...2 0 REPAIRING OVERVIEW ...
Страница 63: ......
Страница 68: ...2 6 FET BOARD 2 6 a Remove top cover per 2 1 2 6 b Remove control board per 2 4 2 6 c Remove DC Plate per 2 5 ...
Страница 73: ......
Страница 74: ......
Страница 75: ......
Страница 76: ......
Страница 77: ......