2. INSTALLATION
2. Pre-Installation, continued
Torque Requirements
T o r q u e a l l A C w i r i n g c o n n e c t i o n s t o 1 6 i n c h p o u n d s . T o r q u e D C c a b l e c o n n e c t i o n s to
10-12 foot pounds.
AC Main Panel
I f t h e i n s t a l l a t i o n w i l l b e p o w e r i n g a w i d e -r a n g e o f a p p l i a n c e s t h r o u g h o u t t h e vehicle,
an AC main panel is often recommended. This is simila r in appearance and f u n c t i o n a s y o u r h o m e ’ s
c i r c u i t b r e a k e r p a n e l , p r o v i d i n g a n a d d i t i o n a l l e v e l o f c o n t r o l a n d p r o t e c t i o n f o r t h e
v a r i o u s c i r c u i t s . A l w a y s r e f e r t o e l e c t r i c a l c o d e s f o r s a f e w i r i n g p r a c t i c e s .
Circuit Protection
I f u s i n g a A C m a i n p a n e l f o r d i s t r i b u t i o n , a l w a y s u s e b r e a k e r s t h a t p r o v i d e t h e
c o r r e c t a m p e r e b r a n c h c i r c u i t p r o t e c t i o n i n a c c o r d a n c e w i t h t h e N a t i o n a l E l e c t r i c
Code. The breakers must also be properly rated for the appliances that will be powered.
N O T E : B o t h A C a n d D C d i s c o n n e c t s / o v e r c u r r e n t p r o t e c t i o n m u s t b e p r o v i d e d a s p a r t o f
t h e i n s t a l l a t i o n .
Wire Routing
D e t e r m i n e a l l w i r e r o u t e s t h r o u g h o u t t h e v e h i c l e b o t h t o a n d f r o m t h e i n v e r t e r .
Conductors that are at risk to physical damage must be protected by conduit, tape, or pla c e d i n a
r a c e w a y . C o n d u c t o r s p a s s i n g t h r o u g h w a l l s , b u l k h e a d s o r o t h e r s t r u c tural members must be
protected to minimize insulation damage such as chafing. D u r i n g t h e i n s t a l l a t i o n , a l w a y s a v o i d
p l a c i n g c o n d u c t o r s n e a r s o u r c e s o f c h a f i n g caused by vibration or constant rubbing.
CAUTION: Always check for existing electrical, plumbing or other areas of potential damage prior to
making cuts in structural surfaces, bulkheads or walls.
T y p i c a l r o u t i n g s c e n a r i o s a r e :
AC Input wiring from the shore power source to the inverter
A C I n p u t w i r i n g f r o m a g e n e r a t o r ( o p t i o n a l ) t o t h e i n v e r t e r
D C I n p u t w i r i n g f r o m t h e b a t t e r i e s t o t h e i n v e r t e r
A C O u t p u t w i r i n g f r o m t h e i n v e r t e r t o t h e c o a c h ’ s A C m a i n p a n e l o r t o d e d i c a t e d
circuits
B a t t e r y T e m p e r a t u r e S e n s o r c a b l e ( o p t i o n a l ) f r o m t h e i n v e r t e r t o t h e b a t t e r i e s
R e m o t e C o n t r o l c a b l e ( o p t i o n a l ) t o t h e i n v e r t e r
G r o u n d w i r i n g f r o m t h e i n v e r t e r t o a n e x t e r n a l v e h i c l e g r o u n d
Ó 2003 - Magnum Energy, Inc.
9
Содержание ME Series
Страница 1: ...ME Series Inverter Chargers Operator s Manual ...
Страница 7: ...1 INTRODUCTION Figure 1 ME Series Inverter Charger Ó 2003 Magnum Energy Inc 2 ...
Страница 15: ...10 Ó 2003 Magnum Energy Inc ...
Страница 20: ...combined battery capacity 400 AHr 12 VDC 14 Ó 2003 Magnum Energy Inc ...
Страница 24: ...Ó 2003 Magnum Energy Inc 17 ...
Страница 33: ...Ó 2003 Magnum Energy Inc ...
Страница 45: ...Remote Control for ME Series Inverter Chargers Operator s Manual ...
Страница 47: ......
Страница 50: ...3 Operation Figure 2 Remote Control Font Panel Ó 2003 Magnum Energy Inc 4 ...
Страница 61: ...1 0 TROUBLESHOOTING 1 1 ME SERIES 1 2 RD SERIES 1 3 REMOTE ...
Страница 62: ...2 0 REPAIRING OVERVIEW ...
Страница 63: ......
Страница 68: ...2 6 FET BOARD 2 6 a Remove top cover per 2 1 2 6 b Remove control board per 2 4 2 6 c Remove DC Plate per 2 5 ...
Страница 73: ......
Страница 74: ......
Страница 75: ......
Страница 76: ......
Страница 77: ......