30
©2009 Magnum Energy Inc.
Operation
# -
When a number appears in the second line of the remote it means
the remote doesn’t know what fault the inverter is reporting.
Remedy
- Contact Magnum Technical Support at 425-253-8833
for help with this fault.
note: the numbers in the display above are
just placeholders.
No Comm
- The remote is not receiving any information from the in-
verter
Relay
- The internal transfer relay is not closing even though the
inverter is charge mode. Please call Magnum Technical Support.
Selco Op
- This fault message is displayed when the TCO (Temperature
Cut-Out) opens and causes the inverter to shutdown to protect the internal
power transformer from damage. When the TCO has cooled down, the
inverter will automatically restart and resume operation.
Remedy
- If this fault occurs while inverting, reduce load on the
inverter. If it occurs while charging, turn down the Charge Rate. If
it occurs often ensure the inverter has adequate ventilation and the
internal cooling fans are operational.
•
•
•
•
Figure 5-21, Unknown Fault
Figure 5-22, No Comm
S tatus
N o C om m
No Comm
appears in the LCD; all
LED’s are off.
E R R OR!
# 101
“#”
- A pound/number sign appears
on the bottomline of the remote. The
FAULT (red) light is on and the INV
(green) is off.
Relay
appears on the LCD and the
FAULT (red) LED is on. The INV
(green) LED’s is off.
E R R OR!
R elay
Figure 5-23, Internal Relay Fault
Selco Op
appears on the LCD and
the FAULT (red) LED is on. The INV
(green) LED’s is off.
E R R OR!
S elco Op
Figure 5-24, Selco Op Fault