22
©2009 Magnum Energy Inc.
Operation
5.3.1 Inverter Mode Messages
The inverter/charger will be in the Inverter Mode when AC power (shorepower/util-
ity or generator) is not available or unacceptable to the inverter/charger’s input.
The Inverter Mode messages are Off, Searching and Inverting.
Off
– This message tells you that there is no AC available on the
inverter’s AC output. The inverter function is off and there is no utility/shore
or generator power AC sensed on its input.
Search
– The inverter is in the Search mode, which means the AC loads
on the inverter output are less than the
SETUP: 01 Search
watts
setting. The
search mode function is used to reduce the inverter draw from the battery
and may be turned off at any time if you want full inverter output voltage
available at all times (see the SETUP: 02 section).
Invert
- The inverter is providing AC voltage on its output by inverting
power from the batteries.
•
•
•
Off
appears on the LCD; all LED’s
are off.
Off
12.6V
S earch
12.6V
Search
appears on the LCD. The
INV (green) LED slowly
fl
ashes. The
FAULT (red) is off
Figure 5-3, Search Mode
Invert
12.6V
Invert
appears on the LCD. The INV
(green) LED’s are on solid. The FAULT
(red) LED is off.
Figure 5-4, Inverting Mode
Figure 5-2, Off Mode