Automatic Measurement (AVM-510A)
9-14
To select the noise measurement line:
1.
Press the
Mesmnt
button.
2.
Select NOISE LINE and then turn the knob to select a line between 10 and 35.
3.
Press the
Clr Mnu
button.
The other measurement sets (Color Setup, Frequency Response, and Non Linear) can also sample live
video when forced to do so. Depending on which measurement set has been selected, only certain
ones of the parameters SYNC AMPL, BURST AMPL, PEAK LUMA, NOISE, and BAR or WHITE BAR
AMPL remain active. To force any of these measurement sets to sample live video:
1.
Press the
Mesmnt
button.
2.
Select SELECT SET and then press the
Entr
button.
3.
Select the appropriate signal format and then press the
Entr
button.
4.
Select the appropriate measurement set and then press the
Entr
button.
NOTE:
AUTOMEASURE/AUTO MEAS SET cannot be applied to live video.
AUTOMEASURE/AUTO MEAS SET automatically selects the Color Setup, Frequency
Response, or the Non Linear measurement set. If it does not recognize the signal, it
selects System Video as the measurement set.
5.
Select SIGNAL ID and then turn the knob until the words LIVE VIDEO appear on the display.
6.
Press the
Clr Mnu
to exit.
NOTE:
System Video is the measurement set used by Picture Guard.
Automatically Reporting Measurements
The reporting feature sends measurement data to a PC file or to a printer at scheduled intervals. You
can run reporting all day or for just part of the day. Errors can be reported as they occur and as all
errors are cleared. This section explains how to configure the AVM-510A to generate a report. The
sections that follow explain how to configure a PC or printer to accept reports, and how to schedule a
report.
A report is a printout, either on paper or in an ASCII computer file, of the current measurements. A
report can be generated by any of the following events:
•
It is time for a scheduled report
•
A new error occurs
•
A previously reported error is still an error after a period of time
•
All errors have been cleared (no errors now)
•
The video signal is lost (no sync)
•
The video signal returns
Содержание AVM-510A Series
Страница 16: ...About This Manual 1 4 Notes...
Страница 34: ...Installation 4 6 Notes...
Страница 48: ...Front Panel Operation 5 14 Notes...
Страница 102: ...Viewing Waveforms Vectors and Pictures 7 30 Notes...
Страница 126: ...Automatic Measurement AVM 510A 9 20 Notes...
Страница 139: ...AVM 510A Option T For Transmission Monitoring 11 5 Figure 11 3 Differential Gain Figure 11 4 Differential Phase...
Страница 148: ...AVM 510A C For Component Measurements 12 4 Notes...
Страница 158: ...Connector Pinouts B 4 Notes...
Страница 162: ...Calibration D 2 Notes...