Automatic Measurement (AVM-510A)
9-8
9.
Press the
Entr
button to move the cursor to the MIN column and then turn the knob to set the
minimum acceptable value.
10.
Press the
Entr
button to move the cursor to the MAX column and then turn the knob to set the
maximum acceptable value.
While in the MIN and MAX columns, the
Arrow
buttons switch the cursor back and forth
between them. Pressing the
Entr
button moves the cursor from MIN to MAX, or from MAX out
and down to the next parameter name (step 8). Pressing the
Prev Mnu
button moves the cursor to
the parameter in the current row.
11.
After setting all acceptable values, press the
Clr Mnu
button to exit or press the
Prev Mnu
button twice to go back and select another measurement set.
NOTE:
Composite and S-video limits are the same. Whatever limits are set for Input A:
composite using a 625 signal in the Color Setup limits will also be used when Input A:
detects an S-video 625 signal and the Color Setup measurement set is used.
Special Considerations for MultiBurst
The AVM-510A recognizes two standard multiburst signals (FCC multiburst in NTSC and CCIR 18 in
PAL) but can also be set up to automeasure a non-standard multiburst signal. If you want to
automeasure a multiburst signal, you need to set the AVM-510A up to detect either a standard
multiburst or a custom multiburst signal. The following table lists all the applicable combinations.
Automeasurement Setup
Applied Signal
Controlling
Measurement
Set
Multiburst ID
Setting
Frequency
Response
Signal ID
Setting
FCC
Multiburst
CCIR 18
Multiburst of
Another Type
What the AVM-510A Recognizes
AUTO
MEASURE/
AUTO MEAS
SET
Auto detect
Any setting
FCC
multiburst
CCIR 18
Multiburst
AUTO
MEASURE/
AUTO MEAS
SET
Standard
Any setting
FCC
multiburst
CCIR 18
CCIR 18 or
FCC multiburst
AUTO
MEASURE/
AUTO MEAS
SET
Custom
Any setting
Custom
Custom
Custom
Frequency
response
Auto detect
AUTO SIG ID
FCC
multiburst
CCIR 18
Multiburst
Frequency
response
Standard
AUTO SIG ID
FCC
multiburst
CCIR 18
CCIR 18 or
FCC multiburst
Frequency
response
Custom
AUTO SIG ID
Custom
Custom
Custom
Frequency
response
Any setting
CCIR 18 or
FCC multiburst
FCC
multiburst
CCIR 18
CCIR 18 or
FCC multiburst
Frequency
response
Any setting
Multiburst
Custom
Custom
Custom
Содержание AVM-510A Series
Страница 16: ...About This Manual 1 4 Notes...
Страница 34: ...Installation 4 6 Notes...
Страница 48: ...Front Panel Operation 5 14 Notes...
Страница 102: ...Viewing Waveforms Vectors and Pictures 7 30 Notes...
Страница 126: ...Automatic Measurement AVM 510A 9 20 Notes...
Страница 139: ...AVM 510A Option T For Transmission Monitoring 11 5 Figure 11 3 Differential Gain Figure 11 4 Differential Phase...
Страница 148: ...AVM 510A C For Component Measurements 12 4 Notes...
Страница 158: ...Connector Pinouts B 4 Notes...
Страница 162: ...Calibration D 2 Notes...