47-602 F10 and F50 Flow Switches
19
4.4.3 Model F10 Dimensional Specifications
NOTE:
For proper performance, a straight pipe run of 12 pipe diameters upstream
and 3 pipe diameters downstream of the switch is recommended.
Ø 2.62 (67) ± .06 (2)
Vane length dependent
upon line size
1.75
(44)
1.50
(38)
3" Pipe and Up
2" and 2 1/2" Pipe
2" NPT 3000# Bonney Threadolet
or Equal (Supplied by Customer)
Pipe Line Size
(Horizontal Lines Only)
Vane
Width
FLOW
A
5.93 (150)
3.87 (98)
8.46
(214)
A
plugged
B
1.56 (40)
2.50
(63)
10.12
(257)
CONDUIT CONNECTIONS A
Electrical Switches:
NEMA 4X/7/9:
1" NPT
Group B:
1" NPT
Pneumatic Switches:
NEMA 1:
1
/
4
" NPT
All housings rotatable 360°
Line
Dim. B
Equivalent
Size
Max.
Max. Wall
Schedule
2"
1.81 (46)
80
2
1
⁄
2
"
1.94 (49)
160
3"
1.88 (48)
80
3
1
⁄
2
"
1.88 (48)
80
4"
2.00 (51)
120
5"
2.06 (52)
120
6"
2.12 (54)
120
8"
2.19 (56)
100
Over
2.31 (59)
—
8"
3.00 (76) Diameter
2 1/2" ANSI Flange
(to match F10)
2 1/2" ANSI
Mounting Flange
Flow Vane
0.19 (5) Minimum
5.93 (150)
3.87 (98)
8.46
(214)
10.12
(257)
plugged
5.25
(133)
Top of
pipe run
7.38
(187)
A
A
Standoffs (Qty. 3)
Notes:
1. Allow the following for overhead
clearance for cover removal:
NEMA 1 —
8.00 (203)
NEMA 4X/7/9 — 10.00 (254)
Group B —
10.00 (254)
F10 with Flanged Connection
F10 with 2" NPT Connection
Inches (mm)