16
47-602 F10 and F50 Flow Switches
4.4
Specifications
4.4.1 Model F10 Actuating Flow Rates
Water Service
GPM
Model F10 units may be adjusted in service to actuate within the
minimum and maximum flow rates given below. A specific
gravity correction factor is applied for liquids other than water.
(1.00 specific gravity). A vane length equal to the line size of the
horizontal pipe is required.
Pipe Line Size
➀
Flow Increase (GPM)
Flow Decrease (GPM)
Inches
Minimum
Maximum
➁
Minimum
Maximum
2
21
63
16
48
2
1
⁄
2
26
74
20
56
3
32
88
24
65
3
1
⁄
2
38
100
28
75
4
45
120
33
85
5
61
150
43
110
6
79
180
55
130
8
120
230
82
160
10
170
310
110
210
12
230
380
150
250
14
270
430
170
280
16
340
510
220
320
18
430
590
270
370
20
520
690
320
430
22
620
780
380
480
24
730
900
450
550
26
850
1030
520
620
28
980
1160
590
700
30
1110
1290
670
780
➀
Based upon Sch. 40 pipe.
➁
Consult factory for higher flow rates.