20
47-602 F10 and F50 Flow Switches
4.4.4 Model F50 Dimensional Specifications
Inches (mm)
F50 Flow Switch with
3
⁄
4
" or 1" NPT Internal Pipe,
Bronze or Stainless Steel Body
F50 Flow Switch with 1
1
⁄
2
" or 2" NPT Internal Pipe,
Bronze or Stainless Steel Body
Outline Dimensions
Housing
A
B
C*
D
5.93
4.29
NEMA 4X/7/9
(151)
(108)
NEMA 4X/7/9
5.93
4.29
9.75
3.60
Group B
(151)
(108)
(247)
(91)
NEMA 1
4.70
5.00
8.44
3.44
Pneumatic
(119)
(127)
(214)
(87)
Conduit Connections E
Electrical Switches
NEMA 4X/7/9:
1" NPT
Group B:
1" NPT
Pneumatic Switches
NEMA 1:
1
/
4
" NPT
Outline Dimensions
Housing
A
B
C
*
D
5.93
4.29
NEMA 4X/7/9
(151)
(108)
NEMA 4X/7/9
5.93
4.29
10.75
4.60
Group B
(151)
(108)
(273)
(116)
NEMA 1
4.70
5.00
9.44
4.44
Pneumatic
(119)
(127)
(240)
(113)
NOTE:
1. For proper performance, a straight pipe run of 12 pipe
diameters upstream and 3 pipe diameters downstream of
the switch is recommended.
2. For NEMA 4X/7/9 allow 8.00 (203) overhead clearance for
cover removal.
6.25
(158)
*
3.87
(98)
5.93 (150)
7.94
(201)
*
3.00
(76)
2.00
(25)
5.75
(1.46)
Horizontal
lines only
Plugged
A
A
Connection size NPT
(both ends)
6.25
(158)
*
3.87
(98)
5.93 (150)
7.94
(201)
*
3.18
(80)
1.19 (30)
3.81
(97)
Horizontal
lines only
Plugged
A
A
Connection size NPT
(both ends)
* This dimension increases by 2.19" (55) when the
unit is supplied with an HS hermetically sealed
switch with terminal block
* This dimension increases by 2.19" (55) when the
unit is supplied with an HS hermetically sealed
switch with terminal block