21
P41-45:
Flume/weir dimensions
See next pages.
FACTORY DEFAULT:
0
P46
:
Distance between transducer face and level of Q=0
P46
is
always
the distance between the transducer face and the level, where the volume flow is 0. FACTORY DEFAULT:
0
Flume / Weir Dimensions
P40= 00
.
.
.
08
Magnetrol Parshall flumes (GPA1P1 … GPA-1P9)
For further details see the Manual of the Parshall flume
Sensor
P4
6
Sensor
P40= 09
General Parshall flume
0.305 < P42(width) <2.44
0.026
Q[m
3
/s]= 0.372*P42*(h/0.305)
1.569*s
2.5 < P42
Q[m
3
/s]= K*P42*h
1.6
P= 2/3*A
A
h
P46
Sensor
Sensor
P42
P
P40= 10
Palmer-Bowlus (D/2) flume
Q[m
3
/s]= f(h1/P41)*P41
2.5
,
where h1[m]= h+(P41/10)
P04
P46
h
P41
D
D/10
P40= 11
Palmer-Bowlus (D/3) flume
Q[m
3
/s]= f(h1/P41)*P41
2.5
,
where h1[m]= h+(P41/10)
P04
P46
h
P41
D
D/10
P40= 12
Palmer-Bowlus (Rectangular) flume
Q[m
3
/s]= C*P42*h
1.5
,
where C= f(P41/P42)
D
P42
P46
P04
h
D/10
P41
s[m]
K
3.05
2.450
4.57
2.400
6.10
2.370
7.62
2.350
9.14
2.340
15.24
2.320