Barrier MHTM
TM
MicroDrive Access and Parking
Electrical connection
94
9.4.6 Digital
inputs
Technical data
→
See page 36, chapter 4.4.
NOTE!
For barriers with a control unit MGC-Pro the digital
input functions can be freely parameterised. The
control unit MGC-Pro is installed in the following
barrier types:
–
Access Pro, Access Pro L and Access Pro H
–
Parking Pro
For the remaining barrier types the control unit
MGC is installed. Here the inputs are firmly
assigned.
→
For input parameterisation, see separate
document "Description of control units MGC and
MGC Pro for MHTM
TM
MicroDrive barriers".
Factory setting
Clamp
Description
Function
IN1
Input 1
Open low priority
IN2
Input 2
Open low priority
IN3 Input
3
Opening with
vend count
IN4
Input 4
Open high priority
IN5 Input
5
External opening loop
exit
IN6 Input
6
Close
IN7 Input
7
Close
IN8
Input 8
Boom contact
Table 24: Factory settings "Digital inputs"