This message appears in the initial phase of filling the internal cylinder from the external
cylinder, if the station detects no pressure or, while filling the internal cylinder, if the
pressure is too low to fill the internal tank to the required degree.
Maximum recirculation
time exceeded!
Continue?
Maximum anticipated recirculation/recovery time. Check the readings on the pressure
gauges – if they show a pressure, the station may be damaged (contact Magneti Marelli
technical representative), if they show no pressure, the vehicle A/C system or valve set
may be leaking.
Select
ENTER
to continue with the recirculation/recovery phase. Select
STOP/RETURN
to
return to standby mode
Filling time exceeded
Continue?
Close HP valve
Start the A/C system
Open LP valve
These messages appear during filling phase if the target refrigerant quantity was not filled
despite the maximum duration, if
HP-LP
A/C system is selected.
The remaining refrigerant will be sucked in to the system by the compressor. Follow the
indications on the display. Select
ENTER
to continue with the filling phase. Select
STOP/RETURN
to return to standby mode
Filling time
exceeded
Continue?
This message appears during filling phase if the target refrigerant quantity was not filled
despite the maximum duration, if
HP
A/C system is selected.
Select
ENTER
to continue with the filling phase. Select
STOP/RETURN
to return to standby
mode
Filling time
exceeded
Continue?
Select
ENTER
to continue.
Start the A/C system
This message appears during filling phase if the target refrigerant quantity was not filled
despite the maximum duration, if
LP
A/C system is selected.
The remaining refrigerant will be sucked in to the system by the compressor. Follow the
indications on the display.
6.2
Functional messages
Replace the drying filter!
Continue?