background image

 

 

 

 

 

Connect HP/LP ■ 
      HP   LP   □ 

 
Select using 

UP-DOWN 

buttons. Confirm by pressing 

ENTER

. See chapter: 

 

Automatic program (without memory card), 

 

Automatic program (with a memory card), 

 

User program.

 

 

8.2

 

Automatic program (without memory card), 

 
When  entering  the  program  selection  mode  (see 

9  PROGRAMS

)  the  following  menu 

appears:  
 

Auto Progr.       ■ 
User progr. □ 

 
Select using 

UP-DOWN 

buttons.  

Confirm by pressing 

ENTER

 

Specify refrigerant weight ■ 
User vehicles   □ 

 
Select using 

UP-DOWN 

buttons.  

Confirm by pressing 

ENTER

 

Specify refrigerant weight 
Refrig. g       XXXX 

 
Specify the correct refrigerant weight using 

UP-DOWN 

buttons.  

Confirm by pressing 

ENTER

.  

 

Refrigerant qty g: XXXXX 
Vacuum:        XX:XX 

 
Vacuum generation time is calculated based on the refrigerant quantity specified.  
Use 

UP-DOWN 

buttons to select the oil/UV injection program.  

See 

9.5 Programming oil/UV injection phase

.  

Confirm by pressing 

ENTER

 to start the automatic program with manual oil/UV injection.  

 
  

 

Содержание 007950015110

Страница 1: ...ermarket Sp ka z o o Plac Pod Lipami 5 40 476 Katowice Tel 48 032 6036107 Faks 48 032 603 61 08 e mail checkstar magnetimarelli com www magnetimarelli checkstar pl Clima Tech Plus Hd Evolution User s...

Страница 2: ...herefore the only task of the user is to use and maintain the device correctly according to the indications in this manual That is why it is important to stress at the beginning that Before any use of...

Страница 3: ...a shipment of the device to the Magneti Marelli Technical Service on reporting the failure The device must be shipped in appropriate packaging that protects it against possible damage in transport Mag...

Страница 4: ...LIMA TECH TOP in a completely safe way and with maximum efficiency exceptional in other similar equipment The device was not designed for disposal see Glossary section 3 2 Description and layout of co...

Страница 5: ...5 FILTER 16 COMPRESSOR 17 VACUUM PUMP 18 WEIGHT 60 kg 19 OIL INJECTION RESERVOIR 20 USED OIL RESERVOIR 21 UV CONTRAST RESERVOIR 22 EXPANSION VALVE 25 RUBBER HOSE 26 RUBBER HOSE 27 CONDENSER FAN 28 HP...

Страница 6: ...u S LED Power supply STOP BACK LED F A LED Recycling phase indication B LED Emptying phase indication C LED Oil injection indication D LED UV additive injection indication E LED Installation charging...

Страница 7: ...Final vacuum 5 Pa 0 05 mbar Filtration unit 2 filters in series DIMENSIONS 1222x629x628 mm Weight 90 kg Weight HD version 105 kg 3 3 2 Energy consumption Supply voltage 230 V 50 60 Hz Power 770 W 3 3...

Страница 8: ...rant may result in bodily damage and even loosing one s sight Avoid skin contact as low boiling point approx 30oC may cause frostbite Avoid inhaling refrigerant vapors Before connecting the unit to th...

Страница 9: ...ocessing Recycling removal of contamination present in the refrigerant by separation of oil and non condensing substances and single or multiple filtration through a special device which reduces humid...

Страница 10: ...aminated the refrigerant is it may be checked using a special acidity and water content measurement set 4 2 4 Recycling remarks Replace the recycling system filter set regularly see Messages section t...

Страница 11: ...mperature between 5 C and 40 C humidity of up to 50 at 40 C The device shall be operated in a place with sufficient lighting average workshop lighting value shall be 500 750 1000 lx Do not operate the...

Страница 12: ...esigned in such a way that the heaviest components are located in its bottom part which assures low center of gravity Nevertheless there is a risk that inclined device may fall down 5 3 Preparation fo...

Страница 13: ...shows the installed software version date and time for a couple of seconds CLIMA TECH EVO SW xx xx xx xx Then the display shows available resources stand by Refrigerant g xxx 5 5 Switching off To stop...

Страница 14: ...ing tanks without suction pipe have only one valve and therefore must be put with their top down to let the liquid refrigerant flow TANKS Tank with a float Tank without a float Open HP valve on the ma...

Страница 15: ...d Confirm by pressing ENTER Close cylinder valve Follow the on screen instructions Confirm by pressing ENTER Wait Refrigerant recovery from tubes Process finished Confirm by pressing ENTER The maximum...

Страница 16: ...k The valve is automatically energized by the system each time there is non liquefied gas in the tank and their pressure is greater than the calibration pressure The purpose of the non liquefied gasse...

Страница 17: ...tects a pressure growth in the system during vacuum leak test Repair the A C system Select ENTER to continue Select STOP RETURN to return to standby mode Insufficient vacuum Continue mB XXX This messa...

Страница 18: ...e if the target refrigerant quantity was not filled despite the maximum duration if HP LP A C system is selected The remaining refrigerant will be sucked in to the system by the compressor Follow the...

Страница 19: ...sage appears one year after database memory card activation Select ENTER Please contact the distributor Select ENTER to go to standby mode See Replacing memory card Replacing the memory card into a ca...

Страница 20: ...instructions on the display 7 1 1 Memory card functions optional For installed memory card in the automatic program specific car model may be selected from the database Moreover a diagnosis mode is av...

Страница 21: ...1 2 3 4 5 6 7 8 9 Space A B C D E F G H I J K L 0 M N O P Q R S T U V W X Y Z a b z c y x w v u t s r q p o n m l k j i h g f e d UP DOWN...

Страница 22: ...TRY AGAIN and confirm by pressing ENTER to start servicing according to previous maintenance parameters select PREVIOUS SERVICE DATA and confirm by pressing ENTER to display the last vehicle filling p...

Страница 23: ...nfirm by pressing ENTER Specify refrigerant weight User vehicles Select using UP DOWN buttons Confirm by pressing ENTER Specify refrigerant weight Refrig g XXXX Specify the correct refrigerant weight...

Страница 24: ...tered data press and hold ENTER button for 3 seconds while previous overhaul parameters are displayed To add a new user vehicle select one of the empty slots in the model list and confirm by pressing...

Страница 25: ...t using UP DOWN buttons Confirm by pressing ENTER Specify refrigerant weight Refrig g XXXX Specify the correct refrigerant weight using UP DOWN buttons Confirm by pressing ENTER Refrigerant qty g XXXX...

Страница 26: ...See 9 2 1 User vehicles 8 4 User program When entering the program selection mode see 9 PROGRAMS the following menu appears Auto Progr User progr Select using UP DOWN buttons Confirm by pressing ENTE...

Страница 27: ...s displayed Manual Oil UV Synchro Oil Uv Select using UP DOWN buttons Confirm by pressing ENTER If synchronized oil UV feeding option is selected the station will suggest switching into Synchronic oil...

Страница 28: ...is selected the following message is displayed Contrast qty to be introd g 10 Use UP DOWN buttons to select contrast quantity to be introduced Confirm by pressing ENTER The station will suggest going...

Страница 29: ...he system was emptied System leak test is then started Min pressure growth control Oil recovery in process The station will remove used oil to the used oil tank 21 Please wait Recycling finished g XXX...

Страница 30: ...vice automatically switches to the next phase 9 3 2 Manual oil UV injection Oil feeding Check if the quality of oil in the tank is sufficient Press Enter to confirm switching into oil injection phase...

Страница 31: ...a odwo ania Diagnostics NB It is suggested that a diagnosis of the installation is performed even without the expansion card Close HP and LP valves Start the motor and keep the rotational speed at 1...

Страница 32: ...system Disconnect the device from the vehicle A C system Open LP and HP valves Confirm with Enter Warning Refrigerant recovery from tubes This message confirms refrigerant recovery from tubes Close LP...

Страница 33: ...ilures The diagnostics option is available after completing the filling phase or by selecting the appropriate menu option Close LP and HP valves Follow the instructions Press Enter to confirm The mess...

Страница 34: ...g tubes Disconnect HP LP tubes from the system Disconnect the device from the system and confirm with Enter Open LP HP valves Follow the instructions Confirm with ENTER Wait Recovery of refrigerant fr...

Страница 35: ...be from the system Follow the instructions Confirm with ENTER Wait Refrigerant is recovered from the tubes The device recovers the refrigerant still present in the tubes The display will show Close LP...

Страница 36: ...Personalizing report data Select User s data to modify printout header The header may contain 5 to 20 characters Repeat printing User s data Use Up and Down buttons to select the desired option Confir...

Страница 37: ...05 Confirm with ENTER Refrigerant counter Vacuum pump counter Use Up and Down buttons to select the counter to reset Confirm with ENTER If refrigerant counter is selected the display will show the fol...

Страница 38: ...nfirm with ENTER Save data User models Confirm with ENTER Transfer from mainboard to memory card Use Up and Down buttons to select the desired menu Confirm with ENTER Save data Confirm with ENTER Savi...

Страница 39: ...tivities are limited to a minimum and their frequency is very low each activity performed periodically is monitored by counters Once a counter has reached the maximum display will show the following m...

Страница 40: ...ols 1 Phillips screwdriver 2 socket wrenches 12 mm 1 Disconnect the station from the power mains 2 Unscrew 4 screws fixing the bottom panel to the station body and remove the panel 3 Put a tray under...

Страница 41: ...f the stations which are not specifically referred to in this section Required tools 1 Phillips screwdriver 2 socket wrenches 12 mm 19mm 1 Disconnect the station from the power mains 2 Unscrew 4 screw...

Страница 42: ...ceed as follows It is forbidden to perform activities on the device components which are not specifically referred to in this section Required tools 1 Phillips screwdriver 1 Disconnect the device from...

Страница 43: ...ical and electronic equipment manufacturers arrange for appropriate systems for collection of these devices for disposal At the end of life of your product contact your distributor to obtain informati...

Страница 44: ...DIAGRAM Magneti Marelli Aftermarket Sp ka z o o Plac Pod Lipami 5 40 476 Katowice Tel 48 032 6036107 Faks 48 032 603 61 08 e mail checkstar magnetimarelli com www magnetimarelli checkstar pl...

Отзывы: