Flex 4EX2 / 6EX2 MRX CE Instruction Manual
November 2018
Page 27 of 44
4.2.2.4 ON/OFF Pushbutton Function
The user can set any of the two adjacent pushbuttons on the
transmitter to behave like a mechanical ON and OFF rocker or
toggle switch. The ON output relay closes when the ON
pushbutton is pressed (the OFF output relay opens) and the OFF
output relay closes when the OFF pushbutton is pressed (the ON
output relay opens).
See Section 4.2.3.1 on page 29
on how to
set to this function.
4.2.2.5 Brake Function
When the transmitter pushbutton is released from 2nd speed up to 1st speed, both
1st and 2nd speed output relays will open for up to 1 second and then with 1st speed
output relay closed thereafter.
See Section 4.2.3.1 on page 29
on how to set to this
function.
4.2.2.6 External Warning Function
The user can install an external warning device (rotating lights, horn, etc.) to the K10
Function output relay located inside the receiver. The user can choose which
pushbutton pair (or pairs) triggers the external warning device when pressed.
See
Section 4.2.3.1 on page 29
on how to set to this function.
4.2.2.7 Momentary Contact
When the pushbutton is released the corresponding output relay will open or
deactivate. This type of relay action usually applies to external applications such as
the horn and buzzer.
See Section 4.2.3.2 on page 30
on how to set to this function.
4.2.2.8 Toggled Contact
When the pushbutton is released the corresponding output relay will maintain
contact or closure until the user presses the same pushbutton again. This type of
relay action usually applies to external applications such as lights.
See Section
4.2.3.2 on page 30
on how to set to this function.