4.2.5
Other Function Output Relays Settings
Listed below are other types of functions that can be outputted through the K10
Function output relay via the infrared IR programmer unit. Contact Magnetek field
service for more details.
LV
→
Function relay closes when receiver voltage is low.
ID
→
Function relay works simultaneously with all motion commands.
NORMAL
→
START fu AUX with normal momentary output.
TOGGLE
→
START fu AUX with toggled/latching output.
TOG&E
→
START fu AUX with toggled/latching output affected by the STOP
command (Function relay opens when STOP button is pressed down).
S/P
→
Function relay closes when START command is executed and opens only when
transmitter power is turned off.
EXT
→
Function relay works simultaneously with the receiver MAIN relays.
HORN
→
Function relay closes for up to 3 seconds when START command is executed
at transmitter power on and then becomes a normal momentary output thereafter.
G SENSOR
→
Function relay closes when Zero-G sensor is triggered (receiver MAIN
relays deactivated) and opens when receiver MAIN relays are reactivated.