background image

 

Enrange Flex EM/EX Instruction Manual 

April 2019 

Page 2 of 19 

SERVICE INFORMATION

 

Your New Radio Remote Control System

 

Thank you for your purchase of Magnetek’s Enrange

®

 brand Flex Radio Remote Equipment Control. 

Magnetek has set a whole new standard in radio-remote performance, dependability, and value with this 
unique new line of handheld transmitters. 
 
If your product ever needs modification or service, please contact one of our representatives at the 
following locations: 
 

U.S. Service Information 

For questions regarding service or technical information contact: 
1-866-MAG-SERV 
(1-866-624-7378) 

International Service 

262-783-3500 

World Headquarters: 

Magnetek, Inc. 
N49 W13650 Campbell Drive 
Menomonee Falls, WI 53051 

Telephone:

  

800-288-8178 

Website

:  

www.magnetek.com 

E-mail:

  

[email protected] 

Fax Numbers:

 

Main:

    

 800-298-3503 

Sales:

    

 262-783-3510 

Service:

  

 262-783-3508 

Canada Service Information: 

161 Orenda Road  
Unit 1  
Brampton, Ontario  
L6W 1W3 Canada  
Phone: 800-792-7253  
Fax: 905-828-5707 
416-424-7617 (24/7 Service pager)  
 

EU Market Contact: 

Brian Preston 
Magnetek (UK) Ltd. 
Unit 3 Bedford Business Centre 
Mile Road 
Bedford, MK42 9TW UK 
Phone: +44-1234-349191 

©2019 MAGNETEK 

All rights reserved. This notice applies to all copyrighted materials included with this product, including, 
but not limited to, this manual and software embodied within the product. This manual is intended for the 
sole use of the person(s) to whom it was provided, and any unauthorized distribution of the manual or 
dispersal of its contents is strictly forbidden. This manual may not be reproduced in whole or in part by 
any means whatsoever without the expressed written permission of MAGNETEK. 

Содержание flex 12em

Страница 1: ...Flex EM EX Transmitter Engineered Remote Equipment Control Part Number 191 00424 0001 R01 April 2019 2019 Magnetek Material Handling...

Страница 2: ...88 8178 Website www magnetek com E mail mhcustomerservice magnetek com Fax Numbers Main 800 298 3503 Sales 262 783 3510 Service 262 783 3508 Canada Service Information 161 Orenda Road Unit 1 Brampton...

Страница 3: ...9 BATTERY DISPOSAL 9 3 GENERAL TRANSMITTER INFORMATION 10 3 1 EXTERNAL ILLUSTRATION 12 Button CONFIGURATION 10 3 2 INTERNAL ILLUSTRATION 12 Button CONFIGURATION 11 3 3 TYPES OF BUTTONS 11 4 DIP SWITCH...

Страница 4: ...equipment where the radio system is used Plant safety rules and procedures of the employers and the owners of facilities where the Magnetek Products are being used Regulations issued by the Occupation...

Страница 5: ...ntenance procedure practice etc which if not strictly observed could result in damage to or destruction of equipment or loss of functional effectiveness Cautions are highlighted as shown below CAUTION...

Страница 6: ...NOT DESIGNED TO INTERFACE DIRECTLY TO TWO STATE SAFETY CRITICAL MAINTAINED FUNCTIONS I E MAGNETS VACUUM LIFTS PUMPS EMERGENCY EQUIPMENT ETC A MECHANICALLY LOCKING INTERMEDIATE RELAY SYSTEM WITH SEPAR...

Страница 7: ...zes the radio control Know how to keep the operator and other people clear of lifted loads and to avoid pinch points Continuously watch and monitor status of lifted loads Know and follow cable and hoo...

Страница 8: ...E OPERATION TEST At the start of each work shift or when a new operator takes control of the crane operators should do as a minimum the following steps before making lifts with any crane or hoist Test...

Страница 9: ...a heating source 2 8 BATTERY CHARGING For those transmitters equipped with battery chargers please familiarize all users with the instructions of the charger before attempting to use Do not attempt to...

Страница 10: ...tton 1 4 Push Button 3 5 Push Button 5 6 Push Button 7 7 Push Button 9 8 Push Button 11 9 Push Button 2 10 Push Button 4 11 Push Button 6 12 Push Button 8 13 Push Button 10 14 Push Button 12 15 Strap...

Страница 11: ...M or EX will differ slightly 3 3 TYPES OF BUTTONS Both the Flex EM and EX are offered in a number of button configurations They can be in four button eight button or twelve button configurations The i...

Страница 12: ...eceiver must be set up to recognize the transmitter on its new channel Top slot 1 Bottom slot 0 Figure 5 The above dip switch setting 1 0 0 1 0 corresponds to channel 19 in the system channels table S...

Страница 13: ...side of the transmitter handset and rotate it clockwise to the On position Figure 8 Figure 9 3 After turning on the transmitter power check the Status LED on the transmitter handset for any sign of sy...

Страница 14: ...period of inactivity push button not pressed defined by the dip switch the receiver E Stop will be disconnected and the unit must cycle power before turning on again 8 Turn off the transmitter power...

Страница 15: ...mitter The button that is active will be designated by the D C B A LEDs See Section 5 4 5 3 red blinks followed by a 2 second pause I CHIP error 6 4 red blinks followed by a 2 second pause Transmittin...

Страница 16: ...e Statement Part 15 19 This device complies with Part 15 of FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accep...

Страница 17: ...433 950MHZ 10011 05 433 200MHZ 00100 21 434 000MHZ 10100 06 433 250MHZ 00101 22 434 050MHZ 10101 07 433 300MHZ 00110 23 434 100MHZ 10110 08 433 350MHZ 00111 24 434 150MHZ 10111 09 433 400MHZ 01000 25...

Страница 18: ...transmitter push button is pressed Improper startup settings Transmitter low battery power Check the transmitter battery level Emergency stop button activated prior to startup Prior to turning on the...

Страница 19: ...1 65 EU The standards relevant for the evaluation of the product referenced above conformity to the directive requirements are as follows EN 301 489 3 v1 4 1 2002 04 EN 301 489 17 v2 1 1 2009 05 EN 30...

Отзывы: