2/12

LH72 initial Setup Manual

Items

Indication

Description

Setting

Addition display

Selection of addition axis, addition 
conditions, etc.

If you select LATHE (lathe function) in 
the type selection, this item will 
appear.

2: No addition, count value of the 2nd axis

3: No addition, count value on the 3rd axis

2 Add 3: Count value of 2nd axis + 3rd axis

2 Add -3: Count value of 2nd axis-3rd axis

-2 Add 3: 3rd axis-2nd axis count value

-2Add-3: -2nd axis -3rd axis count value

Destination country

Please select the region to be used.
(Displayable units)

Std: General Area

US: U.S.A.

JPN: Japan

Measuring unit 
resolution

Set the resolution output from the 
measurement unit to be used for 
each axis.
The resolutions that can be selected 
are length and angle.
Expanded selections increase the 
number of options.

Length: 0.05 to 100μm

*See Tables 1, 2 and 3

or

Angle: 1 second to 1 degree

*Angular resolution (1sec to 1 degree) when 

using a rotary scale

Measuring Unit

Output 

resolution

connection 

cable

Adapter *

SR-1711
SR-1711R

0.5μm

HK-**C
HK-**CR

SZ05-T01

SR801/ MSS-101
SR801R

0.5μm

HK-1**C
HK-2**C

SZ05-T01

SR801/ MSS-101
SR801R

0.5μm

CE07-**C

SZ51-MS01
+ SZ70-1

SR10 / SR30 / 
SR50
SR50-R

0.5μm

HK-4**C
HK6-**CR

SZ05-T01

SR118

0.5μm

CE05-**C
CH02-**

DZ51
+  SZ70-1

SR108
SR107

0.5μm

SZ51-MS01
+ SZ70-1

SR128

0.5μm

CH01-**C

SZ70-1

SR128 / SR127

0.5μm

CH01-LW**C

SZ51-MS01
+  SZ70-1

SR138R(GB-ER)

0.5μm

CH04-03C

Preparations before making the initial setting (1/2)

By confirming the conditions of use in advance, the setting operation can be performed easily.
Let's start with the basic settings.

Basic Setting Items

default

Table1: Length scale output resolution

* For adapter information, refer to Appendix 2 Adapter Connection in this Manual

Measuring Unit

Output 

resolution

Adapter/

conversion cable

Adapter *

SL110
SL130

10μm

PL20B

SZ70-1

SL110
SL130

10μm

PL20C

SJ300

1μm

CH33-**CPD/CED

SJ700

5μm

SZ70-1

SJ700A

5μm

Table 2: Digiruler output resolution

Measuring Unit

Output 

resolution

Adapter/

conversion cable

Adapter *

DG-B

0.5μm

DZ-51

SZ70-1

DL310B/330B

10μm

DZ-51

SZ70-1

DK series

0.1μm or 
0.5μm

CE29-**

Table3: Digital gage output resolution

Содержание LH72

Страница 1: ...of use 2 to 3 How to set up Basic Settings 4 to 6 How to set up Detailed Settings continued from Basic Settings 7 Factory Default All Clear 9 Appendix 1 Front panel Alarm indication 10 Appendix 2 Ada...

Страница 2: ...Output resolution connection cable Adapter SR 1711 SR 1711R 0 5 m HK C HK CR SZ05 T01 SR801 MSS 101 SR801R 0 5 m HK 1 C HK 2 C SZ05 T01 SR801 MSS 101 SR801R 0 5 m CE07 C SZ51 MS01 SZ70 1 SR10 SR30 SR...

Страница 3: ...lections 1000 m m SEG Err segmented error compensation Flicker control Flicker prevention function for the smallest display digit OFF Function stop 1 Weak 2 Strong Sleep The display turns off when the...

Страница 4: ...ngs Detailed Settings will be reset to the factory defaults Configure the basic settings Choose one of the following methods of operation Connecting the AC Adapter AC primary power source Standby key...

Страница 5: ...m 0 1 m 10 m 5 m 1 m 10 minutes 1 minute 10 seconds 1 second How to view extended settings For extended settings press key EDIT when the input resolution of each axis is displayed 2 m 100 m 50 m 25 m...

Страница 6: ...of the basic setting mode LH72 Step 3 Once you have completed the basic settings exit this mode and move to Detailed Setting mode How to set up Basic Settings 3 3 How to Exit Basic Setting Mode Press...

Страница 7: ...ensation Error compensation off Linear compensation Linear Error Segmented error compensation Segmentation Error Error Setting compensation value Selection of error compensation function default Input...

Страница 8: ...allest digits can be suppressed in two stages default 1 min none 10 min 1h 5 min 30 min If no operation or scale movement is performed for a certain period of time the display will turn off default 6...

Страница 9: ...lear perform the following operations Make preparation such as taking notes in advance for necessary items Also do not perform any operation other than the explanation Factory Default All Clear Mainly...

Страница 10: ...Tool coordinates Tool number Datum point value setting key EDIT key REF key Standby key Display Status Display Status Measurement unit not connected Storage data error Speed over Note Error in referen...

Страница 11: ...crews Use screws to secure it in place Use screws to secure it in place SZ70 1 Use screws to secure it in place Scale Head Resolution Adapter Counter SR128 GB A 0 5 m SZ70 1 LG20 LH70 71 71A 72 LY71 7...

Страница 12: ...mp Connector Connector Screws SZ05 T01 connector Cable 300mm SZ70 1 Counter unit Head amp Screws Cable 300mm Counter unit Use screws to secure it in place Use screws to secure it in place Use screws t...

Отзывы: