2
Y-2 Yoke
Operating Manual
English
PRECAUTIONS
Inspect yoke before each use. If damage is present, see maintenance section for instructions.
WARNING
Yoke produces a strong magnetic field.
WARNING
Persons with pacemakers or medical implants must stay 1.5 ft / 0.5 m
away from yoke during operation.
WARNING
Immersing the yoke in liquid of any kind can result in electrical shock. Do
not use yoke in the rain.
CAUTION
GFCI / GFI / RCCB / ELCB protection is recommended to prevent
electrical shock.
CAUTION
Do not exceed the rated duty cycle. Continuous use of the yoke over
extended times will generate excessive heat and may permanently
damage the yoke.
CAUTION
Do not abuse cord. Never carry yoke by cord or yank to disconnect from
receptacle. Never retrieve yoke by pulling on cord. A suspension loop is
provided on the housing above the front coil to accommodate a belt clip
or hanger loop.
CAUTION
Only use outdoor rated extension cords
SW-A, SOW-A, STW-A, STOW-A, SJW-0A, SJOW-A, SJTW-A, or SJTOW-A
Cord Rating 0-6 A
0-25 ft / 0-7.6 m
18 AWG / 0.75 mm min
26-100 ft / 7.6-30.4 m
16 AWG / 1.5 mm min
101-150 ft / 30.4-45.7 m
14 AWG / 2.5 mm min
SPECIFICATIONS
Waveform
AC
Magnetic Field
> 2 kA/m RMS
Lift Strength
> 10 lb / 4.5 kg / 44 N
Leg Span / Pole Spacing
2.5-10.5 in / 6.4-26.7 cm
Leg / Pole Contact Size
1.00 x 0.75 in / 25.4 x 19.0 mm
Cord Length
12 ft / 3.6 m
Duty Cycle
50%, maximum on time 90 sec
Ingress Protection (EN60529)
IP54
Weight
4.9 lb / 2.2 kg
6.2 lb / 2.8 kg (with cord)
Electrical
115V
60 Hz
50 Hz
4.3A maximum
6.3A maximum
230 V
50/60 Hz 2.6A maximum