1.3 Product Label
As defined in the standard EN 60974-1, the duty cycle rate includes a time period of 10 minutes.
For example, if a machine specified as 250A at %60 is to be operated at 250A, the machine can weld / cut
without interruption in the first 6 minutes of the 10 minutes period (zone 1). However, the following
4 minutes should be kept idle for the machine cool down (zone 2).
Duty Cycle
Temperature (C°)
6 min.
6 min.
6 min.
4 min.
4 min.
4 min.
Time (min.)
Duty Cycle
Open Circuit Voltage
Rated Welding Current
Mains Voltage and Frequency
Protection Class
Rated Welding Voltage
Rated Power
Rated Mains Current
X
U0
I
2
U1
IP21S
U2
S1
I
1
Three Phase Transformer Rectifier
Direct Current
Horizontal Characteristic
MIG / MAG Welding
Mains Input 3-Phase Alternating Current
Suitable for Operation at Hazardous
Environments
Technical Information